{"product_id":"siemens-6es7522-5eh00-0ab0-dq-16x24-48vuc-125vdc-st","title":"Siemens 6ES7522-5EH00-0AB0 SIMATIC S7-1500 DQ 16x24-48VUC\/125VDC\/0.5A ST Digital Output PLC I\/O Module","description":"\u003cp\u003eThe Siemens 6ES7522-5EH00-0AB0 is a SIMATIC S7-1500 digital output module, DQ 16x24...48VUC\/125VDC\/0.5A ST, with 16 transistor outputs wired in groups of 1 channel and rated for 24 V, 48 V, or 125 V DC as well as 24\/48 V AC. It switches 0.5 A per channel and supports safety-related shutdown of load groups up to SIL2 per EN IEC 62061 and Category 3\/PL d per EN ISO 13849-1.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7522-5EH00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eDQ 16x24...48 V UC\/125 V DC\/0.5 A ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHW Functional Status\u003c\/td\u003e\n\u003ctd\u003efrom FS01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware Version\u003c\/td\u003e\n\u003ctd\u003efrom V1.0.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e16, transistor, current-sinking and sourcing, grouped in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24, 48, 125 V DC or 24\/48 V AC (50-60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Capacity, Resistive Load\u003c\/td\u003e\n\u003ctd\u003e0.5 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Current per Group\u003c\/td\u003e\n\u003ctd\u003e0.5 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Current per Module\u003c\/td\u003e\n\u003ctd\u003e8 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Delay\u003c\/td\u003e\n\u003ctd\u003e5 ms 0-to-1 and 1-to-0, max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Performance Level\u003c\/td\u003e\n\u003ctd\u003ePL d per ISO 13849-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eSIL 2 per IEC 62061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption, Backplane Bus\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e3.8 W typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Test Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1000 m shielded max., 600 m unshielded max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Horizontal\u003c\/td\u003e\n\u003ctd\u003e-25 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (WxHxD)\u003c\/td\u003e\n\u003ctd\u003e35 x 147 x 129 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Weight\u003c\/td\u003e\n\u003ctd\u003e230 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eST in the product designation places this module in the Standard performance class, one step above BA (Basic) modules such as a plain DQ 64x24VDC output card, adding per-channel isolation (each of the 16 channels is its own potential-separated group) and the SIL2\/Cat.3\/PL d safety-related tripping rating from FS02 onward. That per-channel isolation is what lets the module accept mixed voltage classes on different channels within its 24-48 V UC\/125 V DC range, unlike a fixed single-voltage output card. Choose it over a BA-class output module when individual channels drive different voltage loads or when a channel's shutdown state needs to reach a safety-rated PL d\/SIL2 outcome; where all channels share one supply voltage and no safety rating is needed, a BA-class module costs less rack space per channel.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMixed-voltage output wiring where individual 24 V, 48 V, or 125 V DC loads share a rack, including safety-related shutdown paths that need SIL2\/PL d certified tripping from the standard control CPU.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960649670939,"sku":"6ES7522-5EH00-0AB0","price":1045.27,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7522-5eh00-0ab0-dq-16x24-48vuc-125vdc-0-5a-st-module.png?v=1789798258","url":"https:\/\/stoklink.com\/products\/siemens-6es7522-5eh00-0ab0-dq-16x24-48vuc-125vdc-st","provider":"Stoklink","version":"1.0","type":"link"}