{"product_id":"siemens-6es7522-1bf00-0ab0-dq-8x24vdc-2a-hf-module","title":"Siemens 6ES7522-1BF00-0AB0 SIMATIC S7-1500 DQ 8x24VDC\/2A HF PLC I\/O Module","description":"\u003cp\u003eThe Siemens SIMATIC S7-1500 6ES7522-1BF00-0AB0 (DQ 8x24VDC\/2A HF) is an 8-channel transistor digital output module rated 24 V DC at 2 A per channel, 8 A per group, with PWM output on up to 2 channels and short-circuit protection. It supports safety-related shutdown of load groups to SIL 2 \/ PL d (Category 3) when tripped by an F-CPU, and mounts in a 35 mm wide S7-1500 backplane slot.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7522-1BF00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDQ 8x24VDC\/2A HF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (permissible range 19.2 ... 28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8, transistor, current-sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Capacity, Resistive Load, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent per Channel \/ Group \/ Module, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A \/ 8 A \/ 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePWM Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 channels, 2 ... 100 ms cycle, 0.1% duty resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Delay, Resistive Load (0-1 \/ 1-0), typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 µs \/ 300 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety-Related Tripping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 2 (IEC 62061), PL d \/ Cat. 3 (ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption, Backplane Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 W (6.8 W with PWM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Horizontal Install\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 ... 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Vertical Install\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 ... 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 x 147 x 129 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eHF in the designation denotes the high-feature output module - the PWM function (2 channels, 2-100 ms cycle, 0.1% duty resolution) and the SIL 2 \/ PL d safety-related tripping support are features a standard (non-HF) 8x24VDC output module does not carry, so choose this variant specifically when a load needs PWM-controlled dimming or positioning, or when the output group must be safely shut down by an F-CPU. At 2 A per channel \/ 8 A per group, it suits DC solenoids, contactor coils, and small motor starters; group loads that together exceed 8 A need a second output group or a higher-current module.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eDrives 24 V DC loads such as valve solenoids, indicator lamps, small DC motors, and contactor coils, including PWM-based dimming or positioning outputs and load groups requiring SIL 2 \/ PL d safety-related shutdown.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960647868699,"sku":"6ES7522-1BF00-0AB0","price":248.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7522-1bf00-0ab0-dq-8x24vdc-2a-module.png?v=1789680064","url":"https:\/\/stoklink.com\/products\/siemens-6es7522-1bf00-0ab0-dq-8x24vdc-2a-hf-module","provider":"Stoklink","version":"1.0","type":"link"}