{"product_id":"siemens-6es7431-1kf10-0ab0-sm-431-8ai-14-bit-multi","title":"Siemens 6ES7431-1KF10-0AB0 SIMATIC S7-400 SM 431 8AI 14-Bit U\/I\/R\/TC\/RTD PLC I\/O Module","description":"\u003cp\u003eThe Siemens 6ES7431-1KF10-0AB0 SIMATIC S7-400 SM 431 module provides 8 isolated analog inputs at 14-bit resolution, reading voltage, current, resistance, thermocouples (types B, E, J, K, L, N, R, S, T, U) and RTDs (Pt100\/200\/500\/1000\/10000, Ni100\/1000) on the same channels. Parameterizable temperature compensation supports an external Pt100 sensor or a compensation socket.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad voltage L+ – Rated value (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V; Only required for supplying 2-wire transmitters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad voltage L+ – Reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current – from load voltage L+ (without load), max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mA; for 8 connected, fully controlled 2-wire transmitters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current – from backplane bus 5 V DC, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss – Power loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog inputs – Number of analog inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog inputs – For voltage\/current measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog inputs – For resistance measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog inputs – permissible input voltage for voltage input (destruction limit), max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 V; 18 V continuous, 75 V for 1 ms (mark to space ratio 1:20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog inputs – permissible input current for current input (destruction limit), max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 mA; Permanent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog inputs – Constant measurement current for resistance-type transmitter, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.67 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges – Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges – Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges – Thermocouple\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges – Resistance thermometer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges – Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), voltages – 1 V to 5 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), voltages – Input resistance (1 V to 5 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), voltages – -1 V to +1 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), voltages – Input resistance (-1 V to +1 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), voltages – -10 V to +10 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), voltages – Input resistance (-10 V to +10 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), voltages – -2.5 V to +2.5 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), voltages – Input resistance (-2.5 V to +2.5 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), voltages – -250 mV to +250 mV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), voltages – Input resistance (-250 mV to +250 mV)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), voltages – -5 V to +5 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), voltages – Input resistance (-5 V to +5 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), voltages – -500 mV to +500 mV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), voltages – Input resistance (-500 mV to +500 mV)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), voltages – -80 mV to +80 mV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), voltages – Input resistance (-80 mV to +80 mV)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), currents – 0 to 20 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), currents – Input resistance (0 to 20 mA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), currents – 4 mA to 20 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), currents – Input resistance (4 mA to 20 mA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – type B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Input resistance (Type B)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Type E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Input resistance (Type E)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Type J\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Input resistance (type J)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Type K\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Input resistance (Type K)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Type L\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Input resistance (Type L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Type N\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Input resistance (Type N)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Type R\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Input resistance (Type R)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Type S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Input resistance (Type S)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Type T\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Input resistance (Type T)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Type U\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), thermocouples – Input resistance (Type U)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistance thermometer – Ni 100\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistance thermometer – Input resistance (Ni 100)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistance thermometer – Ni 1000\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistance thermometer – Input resistance (Ni 1000)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistance thermometer – Pt 100\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistance thermometer – Input resistance (Pt 100)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistance thermometer – Pt 1000\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistance thermometer – Pt 10000\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistance thermometer – Pt 200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistance thermometer – Input resistance (Pt 200)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistance thermometer – Pt 500\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistance thermometer – Input resistance (Pt 500)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistors – 0 to 48 ohms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistors – Input resistance (0 to 48 ohms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistors – 0 to 150 ohms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistors – Input resistance (0 to 150 ohms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistors – 0 to 300 ohms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistors – Input resistance (0 to 300 ohms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistors – 0 to 600 ohms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistors – Input resistance (0 to 600 ohms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistors – 0 to 6000 ohms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes; Usable up to 5000 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ranges (rated values), resistors – Input resistance (0 to 6000 ohms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature compensation – Parameterizable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature compensation – external temperature compensation with Pt100\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature compensation – external temperature compensation with compensations socket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature compensation – dynamic reference temperature value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharacteristic linearization – Parameterizable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharacteristic linearization – for thermocouples\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType B, E, J, K, L, N, R, S, T, U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharacteristic linearization – for resistance thermometer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePt100, Pt200, Pt500, Pt1000, Ni100, Ni1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length – shielded, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 m; 50 m with thermocouples and input ranges ≤ 80 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegration and conversion time\/resolution per channel – Resolution with overrange (bit including sign), max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 bit; with activated filtering: 16 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegration and conversion time\/resolution per channel – Integration time, parameterizable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegration and conversion time\/resolution per channel – Basic conversion time (ms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.1 \/ 23.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegration and conversion time\/resolution per channel – Integration time (ms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16,7 \/ 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegration and conversion time\/resolution per channel – Interference voltage suppression for interference frequency f1 in Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegration and conversion time\/resolution per channel – Basic execution time of the module (all channels released)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e161 ms; 161 \/ 188 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection of signal encoders – for voltage measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes; possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection of signal encoders – for current measurement as 2-wire transducer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection of signal encoders – for current measurement as 4-wire transducer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection of signal encoders – for resistance measurement with two-wire connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes; Line resistances are also measured\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection of signal encoders – for resistance measurement with three-wire connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection of signal encoders – for resistance measurement with four-wire connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eErrors\/accuracies – Temperature error (relative to input range), (+\/-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.004 %\/K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational error limit in overall temperature range – Voltage, relative to input range, (+\/-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.38 %; ±0.38 % at ±80 mV; ±0.35 % at ±250 mV, ±500 mV, ±1 V, ±2,5 V, ±5 V, 1 to 5 V, ±10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational error limit in overall temperature range – Current, relative to input range, (+\/-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.35 %; ±20 mA, 0 to 20 mA, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational error limit in overall temperature range – Resistance, relative to input range, (+\/-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational error limit in overall temperature range – Resistance thermometer, relative to input range, (+\/-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational error limit in overall temperature range – Thermocouple, relative to input range, (+\/-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTC Type B (±14.8 K), TC Type R (±9.4 K), TC Type S (±10.6 K), TC Type T (±2.2 K), TC Type E (±4.0 K), TC Type J (±5.2 K), TC Type K (±7.6 K), TC Type U (±3.5 K), TC Type L (±5.1 K), TC Type N (±5.5 K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic error limit (operational limit at 25 °C) – Voltage, relative to input range, (+\/-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 %; ±0.15 % (±250 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, 1 to 5 V, ±10 V); ±0.17% (±80 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic error limit (operational limit at 25 °C) – Current, relative to input range, (+\/-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 %; ±20 mA, 0 to 20 mA, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic error limit (operational limit at 25 °C) – Resistance, relative to input range, (+\/-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 %; ±0.15 % at 0 to 48 ohms (4-conductor measurement), 0 to 150 ohms (4-conductor measurement), 0 to 300 ohms (4-conductor measurement), 0 to 600 ohms (4-conductor measurement), 0 to 5000 ohms (4-conductor measurement, in range of 6000 ohms); ±0.3 % at 0 to 300 ohms (3-conductor measurement), 0 to 600 ohms (3-conductor measurement), 0 to 5000 ohms (3-conductor measurement, in range of 6000 ohms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic error limit (operational limit at 25 °C) – Resistance thermometer, relative to input range, (+\/-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic error limit (operational limit at 25 °C) – Thermocouple, relative to input range, (+\/-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTC Type B (±8.2 K), TC Type R (±5.2 K), TC Type S (±5.9 K), TC Type T (±1.2 K), TC Type E (±1.8 K), TC Type J (±2.3 K), TC Type K (±3.4 K), TC Type U (±1.8 K), TC Type L (±2.3 K), TC Type N (±2.9 K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotential separation analog inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes; internal\/external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotential separation analog inputs – between the channels and backplane bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotential separation analog inputs – Between the channels and load voltage L+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation – Isolation tested with\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 120 V DC between bus and L+\/M; 2 120 V DC between bus and analog section; 500 V DC between bus and local ground; 500 V DC between analog section and L+\/M; 2 120 V DC between analog section and local ground; 2 120 V DC between L+\/M and local ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions – Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions – Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions – Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeights – Weight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClassifications – Version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClassification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClassifications – eClass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClassifications – eClass (2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis module measures voltage, current, resistance, thermocouples (types B, E, J, K, L, N, R, S, T, U) and RTDs (Pt100\/200\/500\/1000\/10000, Ni100\/1000) on the same 8 channels – pick it when a panel needs mixed temperature and process signals without dedicating separate modules to each sensor type. Parameterizable temperature compensation supports an external Pt100 reference, a compensation socket, or a dynamic reference value for thermocouple cold-junction correction. Resolution is 14 bit standard, extending to 16 bit with filtering enabled, and basic conversion time is 20.1\/23.5 ms per channel. Keep cable runs to 50 m (rather than the standard 200 m) when using thermocouples or the ±80 mV range, since low-level signals are more susceptible to noise pickup over longer runs.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960598487323,"sku":"6ES7431-1KF10-0AB0","price":1757.21,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7431-1kf10-0ab0-sm-431-analog-input-module.png?v=1789782228","url":"https:\/\/stoklink.com\/products\/siemens-6es7431-1kf10-0ab0-sm-431-8ai-14-bit-multi","provider":"Stoklink","version":"1.0","type":"link"}