{"product_id":"siemens-6es7322-5sd00-0ab0-sm322-4do-24v-10ma-ex","title":"Siemens 6ES7322-5SD00-0AB0 SIMATIC S7-300 SM 322 4xDO 24V\/10mA Ex Hazardous Area PLC I\/O Module","description":"\u003cp\u003eThe Siemens 6ES7322-5SD00-0AB0 is a SIMATIC S7-300 SM 322 digital output module with 4 isolated outputs rated 24 V \/ 10 mA, built to drive actuators located in a hazardous area. It draws 160 mA from the 24 V DC load supply, is PTB tested under number Ex-96.D.2093X, and carries an [EEx ib] IIC hazardous-area marking.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog No \/ SKU\u003c\/td\u003e\n\u003ctd\u003e6ES7322-5SD00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eSM 322 digital output module, isolated, for hazardous-area signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad voltage L+\u003c\/td\u003e\n\u003ctd\u003e24 V DC, reverse polarity protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption from L+ (no load), max.\u003c\/td\u003e\n\u003ctd\u003e160 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption from backplane bus (5 V DC), max.\u003c\/td\u003e\n\u003ctd\u003e85 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, typ.\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital outputs\u003c\/td\u003e\n\u003ctd\u003e4, electronically short-circuit protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage, rated\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current, signal 1 (0-60 degC)\u003c\/td\u003e\n\u003ctd\u003e10 mA +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad resistance range, upper limit\u003c\/td\u003e\n\u003ctd\u003e390 Ohm, two-wire connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching frequency, resistive load, max.\u003c\/td\u003e\n\u003ctd\u003e100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length, unshielded, max.\u003c\/td\u003e\n\u003ctd\u003e200 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEx(i) gas group IIC limits\u003c\/td\u003e\n\u003ctd\u003eUo 25.2 V, Io 70 mA, Po 440 mW, Co 90 nF, Lo 6.7 mH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotential separation (channels \/ backplane \/ L+)\u003c\/td\u003e\n\u003ctd\u003e60 V DC\/30 V AC in hazardous area; 400 V DC\/250 V AC in non-hazardous area\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX marking\u003c\/td\u003e\n\u003ctd\u003e[EEx ib] IIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFM marking\u003c\/td\u003e\n\u003ctd\u003eAIS CL.1, DIV 1, GP A,B,C,D; CL.I, DIV 2, GP A,B,C,D T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePTB test number\u003c\/td\u003e\n\u003ctd\u003eEx-96.D.2093X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation, max.\u003c\/td\u003e\n\u003ctd\u003e60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection method\u003c\/td\u003e\n\u003ctd\u003e20-pin front connector required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e40 x 125 x 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe higher 25.2 V open-circuit \/ lower 70 mA short-circuit Ex(i) envelope on this 24 V\/10 mA variant gives more voltage headroom than the other SM 322 output variant's 15 V\/20 mA output, which suits field actuators specified at 24 V with lower current draw rather than 15 V with higher draw — match the actuator's own entity parameters (Ui, Ii, Pi) against this module's Uo 25.2 V \/ Io 70 mA \/ Po 440 mW before pairing them. The 390 Ohm maximum load resistance is nearly double the 200 Ohm limit on the lower-voltage variant, so it tolerates longer field cable runs at rated current.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960576762139,"sku":"6ES7322-5SD00-0AB0","price":826.08,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7322-5sd00-0ab0-sm322-4do-24v-10ma-ex.png?v=1789781905","url":"https:\/\/stoklink.com\/products\/siemens-6es7322-5sd00-0ab0-sm322-4do-24v-10ma-ex","provider":"Stoklink","version":"1.0","type":"link"}