{"product_id":"siemens-6es7222-1bh32-0xb0-sm1222-16do-24vdc","title":"Siemens 6ES7222-1BH32-0XB0 SIMATIC S7-1200 SM 1222 16x24VDC\/0.5A Digital Output PLC I\/O Module","description":"\u003cp\u003eThe Siemens 6ES7222-1BH32-0XB0 is a SIMATIC S7-1200 digital output module (SM 1222) with 16 transistor outputs rated 24 V DC at 0.5 A per channel, expanding a CPU rack with additional discrete outputs. Outputs are not internally short-circuit protected, so external fusing or protection is required per channel.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7222-1BH32-0XB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSM 1222, DQ 16x24 V DC\/0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage, permissible range (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4 - 28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current from backplane bus, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16, in groups of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching capacity, resistive load \/ lamp load, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A \/ 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput voltage for signal \"1\", min.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput delay, \"0\" to \"1\" \/ \"1\" to \"0\", max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 µs \/ 200 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length, shielded \/ unshielded, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 m \/ 150 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth \/ Height \/ Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm \/ 100 mm \/ 75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eMarine Approval\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eEach output switches independently (grouped in ones, not fours), so one shorted or overloaded channel does not drag down its neighbors — but because the module has no internal short-circuit protection, size external fusing per channel at or below 0.5 A to protect the transistor stage. The 200 µs turn-off delay with resistive load suits most contactor and solenoid coils; for higher-frequency switching or lamp loads, check the 5 W lamp-load rating against actual inrush current before wiring incandescent indicators directly.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eDriving 24 V DC loads such as indicator lamps, small relays, and solenoid valves directly from an S7-1200 CPU rack without an external output relay module.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960778252571,"sku":"6ES7222-1BH32-0XB0","price":241.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7222-1bh32-0xb0-sm1222-16do-24vdc.png?v=1789662755","url":"https:\/\/stoklink.com\/products\/siemens-6es7222-1bh32-0xb0-sm1222-16do-24vdc","provider":"Stoklink","version":"1.0","type":"link"}