{"product_id":"siemens-6es7193-7db20-0aa0-terminal-module","title":"Siemens 6ES7193-7DB20-0AA0 ET 200iSP TM-PS-B UC Terminal Module 24V DC 5A Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-7DB20-0AA0 TM-PS-B UC terminal module holds the redundant power supply for SIMATIC ET 200iSP remote I\/O stations, working alongside the TM-PS-A module. It converts an 85-264 V AC supply into 20.4-28.8 V DC at up to 5 A, with isolation tested at 2500 V AC, and carries ATEX and IECEx approvals for Zone 1 gas and Zone 21 dust areas.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7193-7DB20-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200iSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169214537\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eTM-PS-B UC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront mounting\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRail mounting\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of supply voltage\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage range\u003c\/td\u003e\n\u003ctd\u003e85-264 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current at 50 Hz, max.\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current at 60 Hz, max.\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of output voltage\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage range\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current at DC, max.\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of slots\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug-in modules, others\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation tested with\u003c\/td\u003e\n\u003ctd\u003e2500 V AC between control supply voltages and all output voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor cross-section, min.\u003c\/td\u003e\n\u003ctd\u003e0.5 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor cross-section, max.\u003c\/td\u003e\n\u003ctd\u003e4 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e230 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX marking\u003c\/td\u003e\n\u003ctd\u003eII 2 G (1) G Ex eb [ia Ga\/ib] IIC T4 Gb, II 2 G (1) D Ex eb [ia IIIC Da] IIC T4 Gb, I M2 Ex eb [ia\/ib] I Mb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion protection category, gas\u003c\/td\u003e\n\u003ctd\u003eATEX gas explosion protection, Zone 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion protection category, dust\u003c\/td\u003e\n\u003ctd\u003eATEX dust explosion protection, Zone 21, install in corresponding enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eCCC Ex\u003c\/li\u003e\n\u003cli\u003eINMETRO\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-PS-B UC module mounts alongside a TM-PS-A to carry a second, redundant power supply in the same ET 200iSP station, so pick it when the application needs continued operation if one supply fails. Its 2500 V AC isolation rating and ATEX\/IECEx Zone 1 gas and Zone 21 dust approvals make it suited to intrinsically-safe I\/O stations inside hazardous process areas rather than general cabinet-mounted installations.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eET 200iSP stations installed in Zone 1 or Zone 21 hazardous process areas where a redundant 24 V DC supply into the I\/O station is required without leaving the hazardous zone for maintenance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960557134107,"sku":"6ES7193-7DB20-0AA0","price":262.55,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-7db20-0aa0-tm-ps-b-uc-terminal-module.png?v=1789781383","url":"https:\/\/stoklink.com\/products\/siemens-6es7193-7db20-0aa0-terminal-module","provider":"Stoklink","version":"1.0","type":"link"}