{"product_id":"siemens-6es7193-6bp00-0ba0-baseunit-type-a0-bridged","title":"Siemens 6ES7193-6BP00-0BA0 SIMATIC ET 200SP BaseUnit BU15-P16+A0+2B Type A0 24V DC Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6BP00-0BA0 is a SIMATIC ET 200SP BaseUnit, type A0, that carries a digital I\/O module on a 24 V DC potential group bridged in from the terminal to its left. It provides 16 push-in process terminals across a 15 x 117 mm footprint and passes up to 10 A on the P1\/P2 backplane bus.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP00-0BA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBU type A0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHW functional status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrom FS06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage, rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\/10 A miniature circuit breaker, type B or C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent carrying capacity, P1\/P2 bus, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent carrying capacity, process terminals, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotential group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinued from the left (bridged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1; Type A0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor cross-section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14 to 2.5 mm² (AWG 26 to 14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals to P1\/P2 bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation tested with\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e707 V DC (type test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, horizontal installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 ... 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, vertical installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 x 117 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4025515080848\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis BaseUnit bridges its potential group in from the terminal on its left, so it shares the 24 V supply and reference potential of the preceding BaseUnit in the row - use it for modules that stay on the same load group as their neighbor. Pick a new-potential-group BaseUnit instead when a module needs its own fresh 24 V group at that position, for example downstream of outputs that must be individually fused or isolated. The push-in terminals accept 0.14-2.5 mm² (AWG 26-14) conductors, and the 10 A external circuit breaker requirement on the supply line sets the practical current ceiling for the whole potential group, not just this base.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMounts in a SIMATIC ET 200SP station to carry a Type A0 digital I\/O module (16 process terminals) sharing a bridged 24 V DC potential group with the adjacent station position - typical in mixed digital I\/O racks where several modules run off one supply feed.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960541110555,"sku":"6ES7193-6BP00-0BA0","price":20.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6bp00-0ba0-baseunit-type-a0-bridged.png?v=1789662596","url":"https:\/\/stoklink.com\/products\/siemens-6es7193-6bp00-0ba0-baseunit-type-a0-bridged","provider":"Stoklink","version":"1.0","type":"link"}