{"product_id":"siemens-6es7144-6jf00-0bb0-et200eco-pn-ai-8xrtd-tc","title":"Siemens 6ES7144-6JF00-0BB0 SIMATIC ET 200eco PN AI 8xRTD\/TC IP69K Remote I\/O Module","description":"\u003cp\u003eThe Siemens 6ES7144-6JF00-0BB0 is a SIMATIC ET 200eco PN module with 8 RTD\/thermocouple analog inputs on M12-L PROFINET connectors, offering 16-bit resolution and channel-level wire-break diagnostics across a wide RTD and thermocouple range. It supports PROFINET IO with shared device operation across 2 controllers, MRP media redundancy, and S2 system redundancy, and it carries IP67\/IP69K protection for washdown environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7144-6JF00-0BB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200eco PN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware Version\u003c\/td\u003e\n\u003ctd\u003eV5.1.x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Input Types\u003c\/td\u003e\n\u003ctd\u003eNi 100\/1000\/120\/200\/500, Pt 100\/1000\/200\/500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Types\u003c\/td\u003e\n\u003ctd\u003eB, C, E, J, K, L, N, R, S, T, U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Range\u003c\/td\u003e\n\u003ctd\u003e-80 mV to +80 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Input Ranges\u003c\/td\u003e\n\u003ctd\u003e0-150, 0-300, 0-600, 0-3000, 0-6000 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bit incl. sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eInternal, external, fixed reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage, Rated\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage, Range\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption, Rated\u003c\/td\u003e\n\u003ctd\u003e85 mA, without load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss, typ.\u003c\/td\u003e\n\u003ctd\u003e6.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO, IRT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eMRP media redundancy, S2 system redundancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShared Device\u003c\/td\u003e\n\u003ctd\u003eYes, up to 2 controllers, prioritized startup, MSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen IE Communication\u003c\/td\u003e\n\u003ctd\u003eSNMP, DCP, LLDP, ping, ARP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP67\/IP69K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e818 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047623411673\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eEight RTD\/thermocouple channels on one module cover twice the measurement points per PROFINET node of a 4-channel analog module, reducing station count where sensor density is high. S2 system redundancy plus MRP media redundancy keep the module reachable through a controller or cable fault, and shared-device operation lets two PROFINET controllers address it at once. IP67\/IP69K protection adds washdown resistance for food, beverage, or high-pressure cleaning duty cycles.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSuited to distributed temperature monitoring in washdown or hygienic areas needing IP69K protection, and PROFINET networks that require S2 redundancy and media redundancy for uptime.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960532361499,"sku":"6ES7144-6JF00-0BB0","price":719.59,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7144-6jf00-0bb0-et200eco-pn-ai-8xrtd-tc.png?v=1789781174","url":"https:\/\/stoklink.com\/products\/siemens-6es7144-6jf00-0bb0-et200eco-pn-ai-8xrtd-tc","provider":"Stoklink","version":"1.0","type":"link"}