{"product_id":"siemens-6es7144-5kd50-0ba0-et200al-ai-4xrtd-tc","title":"Siemens 6ES7144-5KD50-0BA0 SIMATIC ET 200AL AI 4xRTD\/TC IP67 Remote I\/O Module","description":"\u003cp\u003eThe Siemens 6ES7144-5KD50-0BA0 is a SIMATIC ET 200AL analog input module with 4 channels for RTD (Pt100\/Pt1000\/Ni100\/Ni1000) or thermocouple (types B, C, E, J, K, L, N, R, S, T, U) temperature measurement, each independently configurable. Rated IP65\/67 with M12 5-pole connectors, it mounts directly on machinery and runs from a 24 V DC (20.4-28.8 V) supply across a -30 degC to 55 degC operating range.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7144-5KD50-0BA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200AL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eAI 4xRTD\/TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Input Types\u003c\/td\u003e\n\u003ctd\u003eNi 100, Ni 1000, Pt 100, Pt 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Types\u003c\/td\u003e\n\u003ctd\u003eB, C, E, J, K, L, N, R, S, T, U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Range\u003c\/td\u003e\n\u003ctd\u003e-80 mV to +80 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Input Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 150 ohm, 0 to 300 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bit incl. sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle Time, min. (all channels)\u003c\/td\u003e\n\u003ctd\u003e90 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eInternal, external via compensation socket, fixed reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage, Rated\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage, Range\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption, Rated\u003c\/td\u003e\n\u003ctd\u003e30 mA, without load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss, typ.\u003c\/td\u003e\n\u003ctd\u003e1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP65\/67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection, I\/O\u003c\/td\u003e\n\u003ctd\u003eM12, 5-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection, Supply\u003c\/td\u003e\n\u003ctd\u003eM8, 4-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Test Voltage\u003c\/td\u003e\n\u003ctd\u003e707 V DC, type test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety-Related Tripping Support\u003c\/td\u003e\n\u003ctd\u003ePL d \/ Cat. 3 \/ SIL 2, from FS01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Compliance\u003c\/td\u003e\n\u003ctd\u003eAMS 2750 declared, CQI-9 based on AMS 2750E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047623410959\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe four channels cover RTD types (Pt100\/Pt1000\/Ni100\/Ni1000) and thermocouple types B through U in one module, so a single ET 200AL station handles both sensor classes without a separate thermocouple module. Internal and external compensation-socket cold-junction compensation are both supported, which matters for thermocouple accuracy over the -30 degC to 55 degC operating range. Declared conformity to AMS 2750 and CQI-9 makes it a fit for heat-treatment furnace temperature-uniformity surveys that require those pyrometry standards.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFits furnace and heat-treatment temperature monitoring where AMS 2750 \/ CQI-9 pyrometry compliance is required, and general-purpose RTD or thermocouple sensing on IP67 field-mounted ET 200AL stations.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960531771675,"sku":"6ES7144-5KD50-0BA0","price":428.93,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7144-5kd50-0ba0-et200al-ai-4xrtd-tc.png?v=1789781168","url":"https:\/\/stoklink.com\/products\/siemens-6es7144-5kd50-0ba0-et200al-ai-4xrtd-tc","provider":"Stoklink","version":"1.0","type":"link"}