{"product_id":"siemens-6es7144-5kd00-0ba0-et200al-ai-4xu-i-rtd","title":"Siemens 6ES7144-5KD00-0BA0 SIMATIC ET 200AL AI 4xU\/I\/RTD IP67 Remote I\/O Module","description":"\u003cp\u003eThe Siemens 6ES7144-5KD00-0BA0 is a SIMATIC ET 200AL analog input module with 4 universal channels for voltage, current, or RTD\/resistance measurement, each independently configurable. Rated IP65\/67 with M12 5-pole I\/O connectors and an M8 4-pole power connector, it mounts directly on machinery without a control cabinet and runs from a 24 V DC (20.4-28.8 V) supply across a -30 degC to 55 degC operating range.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7144-5KD00-0BA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200AL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eAI 4xU\/I\/RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V, 1 V to 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA, 4 mA to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Input Types\u003c\/td\u003e\n\u003ctd\u003eNi 100, Pt 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Input Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 150 ohm, 0 to 300 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bit with overrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle Time, min. (all channels)\u003c\/td\u003e\n\u003ctd\u003e8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage, Rated\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage, Range\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption, Rated\u003c\/td\u003e\n\u003ctd\u003e35 mA, without load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEncoder Supply\u003c\/td\u003e\n\u003ctd\u003e4 outputs, 0.5 A per channel, 1 A total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss, typ.\u003c\/td\u003e\n\u003ctd\u003e1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP65\/67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection, I\/O\u003c\/td\u003e\n\u003ctd\u003eM12, 5-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection, Supply\u003c\/td\u003e\n\u003ctd\u003eM8, 4-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e30 x 159 x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e168 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Test Voltage\u003c\/td\u003e\n\u003ctd\u003e707 V DC, type test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety-Related Tripping Support\u003c\/td\u003e\n\u003ctd\u003ePL d \/ Cat. 3 \/ SIL 2, from FS02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047623403463\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe four channels accept voltage (0-10 V, 1-5 V), current (0-20 mA, 4-20 mA), or Pt100\/Ni100 RTD inputs independently per channel, so one module covers mixed sensor types on a machine without separate analog modules for each signal class. From FS02, the module supports safety-related tripping of standard modules to PL d \/ Cat. 3 \/ SIL 2, useful where an external safety relay needs a validated analog trip source. The -30 degC to 55 degC operating range and IP65\/67 rating suit direct field mounting outside a control cabinet.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSuited to machine-mounted analog measurement points - temperature via Pt100\/Ni100, process signals via 0-20 mA or 4-20 mA current loops, or 0-10 V transducers - where IP67 field mounting removes the need for a nearby control cabinet. The safety-related tripping support lets the module feed an external safety relay for functions up to PL d \/ SIL 2.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960531575067,"sku":"6ES7144-5KD00-0BA0","price":382.46,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7144-5kd00-0ba0-et200al-ai-4xu-i-rtd.png?v=1789781161","url":"https:\/\/stoklink.com\/products\/siemens-6es7144-5kd00-0ba0-et200al-ai-4xu-i-rtd","provider":"Stoklink","version":"1.0","type":"link"}