{"product_id":"siemens-6es7141-5ah00-0bl0-et200al-io-link-di-16x24vdc","title":"Siemens 6ES7141-5AH00-0BL0 SIMATIC ET 200AL IO-Link DI 16x24VDC 8xM12 Remote I\/O Module","description":"\u003cp\u003eThe Siemens 6ES7141-5AH00-0BL0 is a SIMATIC ET 200AL digital input module with 16 sink-type 24 V DC channels and IO-Link 1.1 Port Class A wiring through 8 M12 connectors, built for IP65\/67 machine-mounted installation. It transmits 2 bytes of process data per module at a 2.5 ms minimum cycle time and operates from -30 to 55 C.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7141-5AH00-0BL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200AL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047623411352\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eIO-Link DI 16x24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHW functional status\u003c\/td\u003e\n\u003ctd\u003eFS01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware version\u003c\/td\u003e\n\u003ctd\u003eV1.0.x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVendor ID\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice ID\u003c\/td\u003e\n\u003ctd\u003e229380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIODD file\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad voltage 1L+, rated (DC)\u003c\/td\u003e\n\u003ctd\u003e24 V; supplied from 1Us+ of the IO-Link master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad voltage 1L+ range\u003c\/td\u003e\n\u003ctd\u003e18 to 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse polarity protection\u003c\/td\u003e\n\u003ctd\u003eYes; against destruction, encoder supply outputs applied with reversed polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption, rated\u003c\/td\u003e\n\u003ctd\u003e20 mA without load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEncoder supply outputs\u003c\/td\u003e\n\u003ctd\u003e8; supplied from 1Us+ of the IO-Link master, short-circuit protected per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24V encoder supply, output current, max.\u003c\/td\u003e\n\u003ctd\u003e0.7 A total (depends on IO-Link master 1Us+ supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, typ.\u003c\/td\u003e\n\u003ctd\u003e2.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital inputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput type\u003c\/td\u003e\n\u003ctd\u003eP-reading (sink), IEC 61131 type 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage, rated (DC)\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage for signal 0 \/ 1\u003c\/td\u003e\n\u003ctd\u003e-30 to +5 V \/ +11 to +30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current for signal 1, typ.\u003c\/td\u003e\n\u003ctd\u003e3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput delay, 0 to 1 \/ 1 to 0\u003c\/td\u003e\n\u003ctd\u003e1.2 to 4.8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length, unshielded, max.\u003c\/td\u003e\n\u003ctd\u003e30 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectable encoders\u003c\/td\u003e\n\u003ctd\u003e2-wire sensor, quiescent current max. 1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIO-Link protocol\u003c\/td\u003e\n\u003ctd\u003e1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIO-Link port type\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIO-Link transmission rate\u003c\/td\u003e\n\u003ctd\u003e38.4 kBd (COM2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIO-Link cycle time, min.\u003c\/td\u003e\n\u003ctd\u003e2.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess data, input per module\u003c\/td\u003e\n\u003ctd\u003e2 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess data, output per module\u003c\/td\u003e\n\u003ctd\u003e0 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported IO-Link profile\u003c\/td\u003e\n\u003ctd\u003eCommon profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIO-Link cable length, unshielded, max.\u003c\/td\u003e\n\u003ctd\u003e20 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eShort-circuit, sensor supply to M, module by module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation tested with\u003c\/td\u003e\n\u003ctd\u003e707 V DC (type test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP65\/67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature during operation\u003c\/td\u003e\n\u003ctd\u003e-30 to 55 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection, inputs\/outputs and IO-Link\u003c\/td\u003e\n\u003ctd\u003eM12, 5-pin, A-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e45 x 159 x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e155 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIO-Link Port Class A wiring is what separates this module from the plain non-IO-Link 16-channel\/8xM12 variant: it registers on the IO-Link master with its own Vendor ID 42 \/ Device ID 229380, so its 16 inputs and diagnostics appear as IO-Link process and diagnostic data rather than raw I\/O bits alone. Choose it when the station already runs an IO-Link master and centralized IODD-based parameterization or remote diagnostics is wanted for standard digital inputs. The verified data lists no safety-related tripping rating for this module, so it is not a substitute where PLd\/SIL2 triggering from a standard module is required.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960514797851,"sku":"6ES7141-5AH00-0BL0","price":206.72,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7141-5ah00-0bl0-et200al-io-link-di-16x24vdc-8xm12.png?v=1789781032","url":"https:\/\/stoklink.com\/products\/siemens-6es7141-5ah00-0bl0-et200al-io-link-di-16x24vdc","provider":"Stoklink","version":"1.0","type":"link"}