{"product_id":"siemens-6es7138-7fa00-0ab0-et200isp-4f-ai-hart-ex","title":"Siemens 6ES7138-7FA00-0AB0 SIMATIC ET 200iSP 4F-AI HART Ex SIL3 Fail-safe Remote I\/O Module","description":"\u003cp\u003eThe Siemens 6ES7138-7FA00-0AB0 is a fail-safe SIMATIC ET 200iSP analog input module with 4 HART-capable current channels for connecting 2-wire transmitters in intrinsically safe Zone 1 areas, certified SIL 3 per IEC 61508, PLe per ISO 13849-1, and Category 4 per EN 954-1. It runs on 19.2-30 V DC and supports HART protocol version 7.0.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7138-7FA00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200iSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169224161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003e4F-AI I Ex HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage range\u003c\/td\u003e\n\u003ctd\u003e19.2 to 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption, typ.\u003c\/td\u003e\n\u003ctd\u003e315 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current from L+, max.\u003c\/td\u003e\n\u003ctd\u003e490 mA (internal powerbus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter supply current, max.\u003c\/td\u003e\n\u003ctd\u003e25 mA plus 4 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, typ. \/ max.\u003c\/td\u003e\n\u003ctd\u003e3.8 W \/ 5.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddress space, max.\u003c\/td\u003e\n\u003ctd\u003e16 byte (12 byte input, 4 byte output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog inputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA; 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement principle\u003c\/td\u003e\n\u003ctd\u003eIntegrating (Sigma-Delta)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution, with overrange\u003c\/td\u003e\n\u003ctd\u003e16 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegration time\u003c\/td\u003e\n\u003ctd\u003eParameterizable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference frequency suppression\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmoothing of measured values\u003c\/td\u003e\n\u003ctd\u003eParameterizable, 4 stages (1x \/ 4x \/ 16x \/ 64x cycle time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurden, 2-wire transmitter, max.\u003c\/td\u003e\n\u003ctd\u003e750 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity error (+\/-)\u003c\/td\u003e\n\u003ctd\u003e0.015 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature error (+\/-)\u003c\/td\u003e\n\u003ctd\u003e0.005 %\/K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrosstalk between inputs, min.\u003c\/td\u003e\n\u003ctd\u003e-50 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeat accuracy at 25 C (+\/-)\u003c\/td\u003e\n\u003ctd\u003e0.015 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational error limit (+\/-)\u003c\/td\u003e\n\u003ctd\u003e0.35 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic error limit at 25 C (+\/-)\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries mode interference suppression, min.\u003c\/td\u003e\n\u003ctd\u003e40 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode interference suppression, min.\u003c\/td\u003e\n\u003ctd\u003e50 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFIsafe\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic alarm\u003c\/td\u003e\n\u003ctd\u003eYes; parameterizable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnoses\u003c\/td\u003e\n\u003ctd\u003eWire break, short-circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length, shielded, max.\u003c\/td\u003e\n\u003ctd\u003e500 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHighest safety class\u003c\/td\u003e\n\u003ctd\u003eCat. 4 (EN 954-1), PLe (ISO 13849-1), SIL 3 (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX marking\u003c\/td\u003e\n\u003ctd\u003eII 2 G (1) GD Ex ib[ia Ga][ia IIIC Da] IIC T4 GB; I M2 Ex ib[ia Ma] I Mb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX certificate\u003c\/td\u003e\n\u003ctd\u003e10 ATEX 0058\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e30 x 129 x 136.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e299 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eCE\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eHART pass-through lets this module read transmitter diagnostics and secondary variables over the 4-20 mA loop, so pick it over a plain fail-safe current input when HART device configuration or asset data is needed from the field. The SIL 3 \/ PLe \/ Category 4 rating means the fail-safe logic can sit directly in this I\/O module rather than requiring a separate safety PLC downstream. Its Ex ib (ia Ga) IIC T4 Gb marking covers Zone 1 gas areas via the associated-apparatus concept, so 2-wire HART transmitters can be wired directly into the hazardous zone.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960508277019,"sku":"6ES7138-7FA00-0AB0","price":1418.14,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7138-7fa00-0ab0-et200isp-4f-ai-hart-ex.png?v=1789780986","url":"https:\/\/stoklink.com\/products\/siemens-6es7138-7fa00-0ab0-et200isp-4f-ai-hart-ex","provider":"Stoklink","version":"1.0","type":"link"}