{"product_id":"siemens-6es7134-7sd00-0ab0-et200isp-4ai-tc","title":"Siemens 6ES7134-7SD00-0AB0 ET200iSP 4AI TC Thermocouple Ex Zone 1 Remote I\/O Module","description":"\u003cp\u003eThe Siemens 6ES7134-7SD00-0AB0 is an ET200iSP electronic module with 4 analog thermocouple inputs, certified Ex ib [ia Ga] IIC T4 Gb for installation in ATEX and IECEx Zone 1 hazardous areas. It accepts thermocouple types B, C, E, J, K, L, N, R, S, T and U plus a -80 mV to +80 mV voltage range, with 16-bit resolution and internal cold-junction compensation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7134-7SD00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET200iSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4AI TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHW Functional Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirmware Version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV1.0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Analog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage -80 to +80 mV; Thermocouple types B, C, E, J, K, L, N, R, S, T, U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 bit (with overrange)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic Conversion Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 ms at 50 Hz \/ 66 ms at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal (via supplied TC sensor module) or external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, shielded, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire-break Diagnosis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, R greater than 1.7 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII 2 G (1) G Ex ib [ia Ga] IIC T4 Gb, II 2 G (1) D Ex ib [ia IIIC Da] IIC T4 Gb, I M2 Ex ib [ia] I Mb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIECEx Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIECEx KEM 05.0008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\/spring-type terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth x Height x Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 x 129 x 136.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe internal cold-junction compensation via the supplied TC sensor module means this 4AI TC card needs no external compensation socket, unlike modules that rely on a separate analog channel for reference temperature. Its Ex ib [ia Ga] IIC T4 Gb rating restricts it to Zone 1 gas and Zone 21 dust areas rather than Zone 0; pick the HART 2-wire variant instead when the field instrument is a 4-20 mA transmitter rather than a bare thermocouple.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960486224155,"sku":"6ES7134-7SD00-0AB0","price":843.84,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7134-7sd00-0ab0-et200isp-4ai-tc-module.png?v=1789780688","url":"https:\/\/stoklink.com\/products\/siemens-6es7134-7sd00-0ab0-et200isp-4ai-tc","provider":"Stoklink","version":"1.0","type":"link"}