{"product_id":"siemens-6es7132-7rd01-0ab0-et200isp-4do-ex-ib","title":"Siemens 6ES7132-7RD01-0AB0 SIMATIC ET 200iSP 4DO 23.1V DC\/20mA Ex ib Remote I\/O Module","description":"\u003cp\u003eThe Siemens 6ES7132-7RD01-0AB0 is a SIMATIC ET200iSP intrinsically safe electronic module with 4 digital outputs rated 23.1 V DC\/20 mA, plus an integrated intrinsically-safe input for H shutdown. It carries ATEX and IECEx Ex ib [ia Ga] IIC T4 Gb approval for Zone 1 gas and Zone 21 dust areas, mounts on a rail or front panel, and provides screw\/spring-type terminal connections with IP30 protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU (MLFB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7132-7RD01-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET200iSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4DQ 23.1 V DC\/20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSHUT DOWN H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Digital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4, plus 1 intrinsically-safe input for H shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNo-Load Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.1 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.02 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 mA typ., 340 mA max with actuator supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 m max, shielded or unshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEx(i) Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUo 25.6 V, Io 96 mA, Po 0.61 W, Co 98 nF, Lo 3 mH (gas group IIC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII 2 G Ex ib [ia Ga] IIC T4 Gb, II 2 D Ex ib [ia IIIC Da] IIC T4 Gb, I M2 Ex ib [ia] I Mb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\/spring-type terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 x 129 x 136.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe rated output is only 20 mA, so this module is sized for low-power actuators such as solenoid pilots or intrinsically-safe indicator circuits in a hazardous area, not general-purpose switching. Parallel switching of two outputs for uprating is explicitly not possible for Ex reasons, which rules out doubling current capacity the way a non-Ex module might allow. The integrated intrinsically-safe H-shutdown input is a dedicated safety-shutdown channel separate from the 4 standard DO channels, and its own Ex parameters (Ui 28 V, Pi 1.2 W, Ci 3 nF) must be checked against the connected field circuit during loop calculation.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eBuilt for digital output signaling inside ATEX\/IECEx Zone 1 gas or Zone 21 dust areas and IECEx Zone 1 marine\/offshore installations, where field wiring must stay intrinsically safe, such as low-power solenoid or indicator control on process skids, tank farms, and hazardous-area production lines.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960472199451,"sku":"6ES7132-7RD01-0AB0","price":488.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7132-7rd01-0ab0-et200isp-4do-ex-ib.png?v=1789714360","url":"https:\/\/stoklink.com\/products\/siemens-6es7132-7rd01-0ab0-et200isp-4do-ex-ib","provider":"Stoklink","version":"1.0","type":"link"}