{"product_id":"siemens-6es7132-6hd01-0bb1-et200sp-relay-output-module","title":"Siemens 6ES7132-6HD01-0BB1 ET 200SP RQ NO 4x 120-230V\/5A Remote I\/O Module","description":"\u003cp\u003eThe Siemens 6ES7132-6HD01-0BB1 is a SIMATIC ET 200SP relay output module with 4 normally-open relay channels rated 5 A per channel, switching 24-120 V DC or 24-230 V AC loads. It mounts on BaseUnit type B0 (3-wire) or B1 (2-wire) and reports diagnostics for supply voltage monitoring. The relay contacts are galvanically isolated from each other and from the backplane bus.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7132-6HD01-0BB1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eRQ 4x120 VDC ... 230 VAC\/5 A NO ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage, rated (DC)\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage permissible range (DC)\u003c\/td\u003e\n\u003ctd\u003e19.2 V to 28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital output type\u003c\/td\u003e\n\u003ctd\u003eRelays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of digital outputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching capacity, resistive load, max.\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching capacity, inductive load, max.\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated switching voltage (DC)\u003c\/td\u003e\n\u003ctd\u003e24 V DC to 120 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated switching voltage (AC)\u003c\/td\u003e\n\u003ctd\u003e24 V AC to 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of operating cycles, max.\u003c\/td\u003e\n\u003ctd\u003e7,000,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per module, max.\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsable BaseUnits\u003c\/td\u003e\n\u003ctd\u003eBU type B0, B1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, typ.\u003c\/td\u003e\n\u003ctd\u003e1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, horizontal installation\u003c\/td\u003e\n\u003ctd\u003e-30 degC to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, vertical installation\u003c\/td\u003e\n\u003ctd\u003e-30 degC to 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation tested with\u003c\/td\u003e\n\u003ctd\u003e2500 V DC (type test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e20 mm x 73 mm x 58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e40 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe relay output stage gives 24-230 V AC or 24-120 V DC switching on the same 4 channels, so this module covers mixed-voltage loads that a transistor output module cannot switch directly, and the contacts stay isolated from the backplane bus and from each other. Choose BaseUnit B0 for a 3-wire connection or B1 for a 2-wire connection depending on how the load and supply are wired at the terminal block. At 7,000,000 rated operating cycles and 2 A max under inductive load, this variant fits switching duty rather than high-cycle-count applications; for higher current per channel or a transistor-based output, use a different module in the ET 200SP relay\/output lineup.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSuited to decentralized switching of contactors, solenoid valves, indicator lamps, and small motors from an ET 200SP station on PROFINET or PROFIBUS, where the load voltage differs from the station's 24 V DC logic supply and electrical isolation between channels is required.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960465187099,"sku":"6ES7132-6HD01-0BB1","price":91.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7132-6hd01-0bb1-et200sp-relay-output-module.png?v=1789681099","url":"https:\/\/stoklink.com\/products\/siemens-6es7132-6hd01-0bb1-et200sp-relay-output-module","provider":"Stoklink","version":"1.0","type":"link"}