{"product_id":"siemens-6es7132-6gd51-0ba0-et200sp-rq-co-relay-module","title":"Siemens 6ES7132-6GD51-0BA0 SIMATIC ET 200SP RQ CO 4x24 V\/2 A Relay Module","description":"\u003cp\u003eThe Siemens SIMATIC ET 200SP 6ES7132-6GD51-0BA0 is a digital relay output module with 4 changeover contacts, each switching up to 2 A at 24 V DC or AC with contacts isolated from each other. It mounts on BaseUnit type A0, draws 50 mA from a 24 V DC rated supply, and its relays are rated for up to 500,000 operating cycles.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7132-6GD51-0BA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRQ CO 4x24VDC\/2A ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4, relay, changeover (CO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Switching Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC \/ 24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Current per Channel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A maximum, resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Current per Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (19.2...28.8 V range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Operating Cycles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500,000 maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Test Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e707 V DC (type test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length (shielded \/ unshielded)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 m \/ 200 m maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (horizontal mounting)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30...+60 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (vertical mounting)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30...+50 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaseUnit Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBU type A0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 x 73 x 58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eapprox. 30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe four isolated changeover contacts, each independently rated at 2 A, let this module switch small loads across different voltage domains or polarities from one ET 200SP slot without a separate interposing relay, and the type C mechanical coding element on BaseUnit A0 keeps it from being swapped into a slot wired for a different signal type during module replacement. At 8 A total module current against 4 x 2 A per channel, all four outputs can run near their rated current simultaneously without exceeding the shared limit; apply the horizontal 40\/50\/60 degrees C or vertical 30\/40\/50 degrees C current-derating steps in the specification when the cabinet runs warmer than that.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSwitching small motor starters, solenoid valves, indicator lamps, or contactor coils from an ET 200SP station, and isolated relay outputs for mixed-voltage field wiring.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960463810843,"sku":"6ES7132-6GD51-0BA0","price":67.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7132-6gd51-0ba0-simatic-et200sp-relay-module.png?v=1789681093","url":"https:\/\/stoklink.com\/products\/siemens-6es7132-6gd51-0ba0-et200sp-rq-co-relay-module","provider":"Stoklink","version":"1.0","type":"link"}