{"product_id":"siemens-6es7131-6bh01-0ba0-di-16x24vdc-st-input-module","title":"Siemens 6ES7131-6BH01-0BA0 SIMATIC ET 200SP DI 16x24VDC ST 16DI 24V DC Sink Remote I\/O Module","description":"\u003cp\u003eThe Siemens 6ES7131-6BH01-0BA0 is a SIMATIC ET 200SP digital input module with 16 channels of 24 V DC sinking (PNP, P-reading) inputs meeting IEC 61131 type 3 characteristics. It mounts on a Type A0 BaseUnit, reports wire-break and supply-voltage diagnostics, and accepts parameterizable input delays from 0.05 to 20 ms.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7131-6BH01-0BA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDI 16x24VDC ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHW functional status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrom FS02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUsable BaseUnit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSinking (PNP, P-reading), IEC 61131 type 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput voltage, rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput voltage for signal 0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to +5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput voltage for signal 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+11 to +30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current for signal 1, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput delay, parameterizable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05 \/ 0.1 \/ 0.4 \/ 0.8 \/ 1.6 \/ 3.2 \/ 12.8 \/ 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage, rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 to 28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent consumption, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length, shielded\/unshielded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 m \/ 600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWire break, supply voltage, group error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation tested with\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e707 V DC (type test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 x 73 x 58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047623408550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe P-reading (PNP sinking) input type means this module switches on a positive signal referenced to the sensor's 24 V supply - pair it with PNP 2-wire or 3-wire sensors rather than NPN devices, which need the complementary sourcing-input variant. Because the input delay is parameterizable from 0.05 ms up to 20 ms per channel, it can be set fast for position encoders on one channel and slow-filtered for noisy limit switches on another within the same module. The module-by-module wire-break diagnostic needs an external 25-45 kOhm protective circuit on simple contact-only encoders, since the module can't tell an open contact from a broken wire without that resistor bridging the input.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eReads 16 discrete 24 V DC field signals - limit switches, proximity sensors, pushbuttons - into a SIMATIC ET 200SP station on a Type A0 BaseUnit, with PROFINET or PROFIBUS diagnostics for wire-break and supply-voltage faults reported back to the controller.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960455848219,"sku":"6ES7131-6BH01-0BA0","price":115.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7131-6bh01-0ba0-di-16x24vdc-st-input-module.png?v=1789662723","url":"https:\/\/stoklink.com\/products\/siemens-6es7131-6bh01-0ba0-di-16x24vdc-st-input-module","provider":"Stoklink","version":"1.0","type":"link"}