{"product_id":"siemens-6ep4683-6lb00-0ay0-logo-icl230-inrush-limiter","title":"Siemens 6EP4683-6LB00-0AY0 LOGO! ICL230 Inrush Current Limiter 100-240V AC 5A Power Supply","description":"\u003cp\u003eThe Siemens 6EP4683-6LB00-0AY0 is a LOGO! ICL230 inrush current limiter for single-phase 100-240V AC supplies, passing up to 5A continuous while actively limiting inrush current to 10A for 60ms at power-up. It mounts on a DIN rail ahead of downstream power supplies to prevent nuisance tripping of upstream circuit breakers when multiple units switch on together.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP4683-6LB00-0AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP \/ LOGO!\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLOGO! ICL230 Switch-on current limitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-phase AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ... 240 V AC (85 ... 264 V full range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ... 240 V AC (follows input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated output current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current limitation at 25 °C, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush limiting duration at 25 °C, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emax. 2 events\/min continuous; up to 30 events\/min for 1 min, once per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-reversible thermal fuse (overload)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC emission\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 x 90 x 53 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15 or wall mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4025515155485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe ICL230's 5A-rated output means it protects one downstream supply or a small group of supplies whose combined inrush would otherwise trip an upstream breaker on power-up - typical when several SITOP or LOGO! power supplies switch on together from the same feed. Its non-reversible thermal fuse means a sustained overload takes the unit out of service rather than resetting, so it belongs upstream of loads that are not expected to fault repeatedly. Because it passes through the same 100-240V AC voltage it limits, it adds inrush protection without acting as a step-down converter.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePlaced between the mains feed and one or more 24V DC power supplies in a cabinet, it holds the combined inrush current under 10A for the first 60ms so the upstream circuit breaker does not see a nuisance trip when the cabinet is energized.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960775434523,"sku":"6EP4683-6LB00-0AY0","price":76.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4683-6lb00-0ay0-logo-icl230-inrush-limiter.png?v=1789780549","url":"https:\/\/stoklink.com\/products\/siemens-6ep4683-6lb00-0ay0-logo-icl230-inrush-limiter","provider":"Stoklink","version":"1.0","type":"link"}