{"product_id":"siemens-6ep4436-8xb00-0cy0-sitop-cnx8600","title":"Siemens 6EP4436-8XB00-0CY0 SITOP CNX8600 4x5A PSU8600 Expansion Power Supply","description":"\u003cp\u003eThe Siemens 6EP4436-8XB00-0CY0 is a SITOP CNX8600 expansion module that adds four isolated, individually adjustable 24 V DC outputs at 5 A each to a SITOP PSU8600 power supply, without increasing the PSU8600 system's total output power. Each output is adjustable from 4 to 28 V via potentiometer or the PROFINET interface and reports its own operating state on a dedicated LED.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6EP4436-8XB00-0CY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSITOP CNX8600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4025515154488\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eExtension module SITOP CNX8600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Current Supply\u003c\/td\u003e\n\u003ctd\u003e4 x 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage, Rated\u003c\/td\u003e\n\u003ctd\u003e24 V DC per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage, Adjustable\u003c\/td\u003e\n\u003ctd\u003e4 ... 28 V DC per output, via potentiometer or IE\/PN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current, Rated\u003c\/td\u003e\n\u003ctd\u003e20 A total (4 x 5 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e97 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied Active Power\u003c\/td\u003e\n\u003ctd\u003etyp. 480 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003emax. 35 V (max. 500 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eElectronic overload cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Current Threshold, Adjustable\u003c\/td\u003e\n\u003ctd\u003e0.5 ... 5 A, via potentiometer or IE\/PN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation, Output\u003c\/td\u003e\n\u003ctd\u003eSELV, ES1 (IEC 62368-1), DVC As (IEC 61204-7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eEthernet\/PROFINET via PSU8600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF at 40 C\u003c\/td\u003e\n\u003ctd\u003e358372 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/cULus Approval\u003c\/td\u003e\n\u003ctd\u003ecULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Resource Protection Class\u003c\/td\u003e\n\u003ctd\u003eClass III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-25 ... +60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure W x H x D\u003c\/td\u003e\n\u003ctd\u003e60 x 125 x 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eSEMI F47\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eShipbuilding\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eEach of the four outputs can be trimmed independently from 4 to 28 V by potentiometer or over the PROFINET interface, so mixed-voltage loads can be served from one CNX8600 instead of separate supplies. The overload threshold is adjustable per output from 0.5 to 5 A through the same two access methods, letting each trip point be matched to its actual downstream load rather than left at the full 5 A rating. Because the module adds outputs without increasing the PSU8600 system's total power budget, the base PSU8600 unit has to be sized for the combined load before a CNX8600 is added for extra connection points.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960774353179,"sku":"6EP4436-8XB00-0CY0","price":286.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4436-8xb00-0cy0-sitop-cnx8600-power-supply.png?v=1789780966","url":"https:\/\/stoklink.com\/products\/siemens-6ep4436-8xb00-0cy0-sitop-cnx8600","provider":"Stoklink","version":"1.0","type":"link"}