{"product_id":"siemens-6ep4197-8ab00-0xy0-sitop-ups8600","title":"Siemens 6EP4197-8AB00-0XY0 SITOP UPS8600 48V\/960W PSU8600 UPS Power Supply Module","description":"\u003cp\u003eThe Siemens 6EP4197-8AB00-0XY0 is a SITOP UPS8600 UPS module that plugs into a SITOP PSU8600 power supply and buffers its 48 V DC output at up to 960 W using external BAT8600 battery modules. Its charger delivers up to 120 W to recharge the batteries, and buffer time is set from 1 to 88 minutes by DIP switch or until the batteries are discharged.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6EP4197-8AB00-0XY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS8600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4025515155102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Current Supply\u003c\/td\u003e\n\u003ctd\u003e960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Storage\u003c\/td\u003e\n\u003ctd\u003eExternal battery module (BAT8600)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffer Time, Adjustable\u003c\/td\u003e\n\u003ctd\u003e1 ... 88 min via DIP switches, or until batteries discharged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage, Normal Operation\u003c\/td\u003e\n\u003ctd\u003e48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Short-Circuit Proof\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Current\u003c\/td\u003e\n\u003ctd\u003e1.25 A, 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eRelay contacts (NO, DC 60 V\/0.3 A) for buffer readiness, buffer mode, battery circuit fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency on Battery Operation\u003c\/td\u003e\n\u003ctd\u003etyp. 99 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss on Battery Operation\u003c\/td\u003e\n\u003ctd\u003etyp. 10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied Active Power\u003c\/td\u003e\n\u003ctd\u003etyp. 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eEthernet\/PROFINET via PSU8600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF at 40 C\u003c\/td\u003e\n\u003ctd\u003e405763 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/cULus Approval\u003c\/td\u003e\n\u003ctd\u003ecULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Resource Protection Class\u003c\/td\u003e\n\u003ctd\u003eClass III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-25 ... +70 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure W x H x D\u003c\/td\u003e\n\u003ctd\u003e60 x 125 x 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eShipbuilding\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBuffer time is set from 1 to 88 minutes by DIP switch, or the module can be left to run until the attached BAT8600 batteries are fully discharged, so the same hardware covers both a short controlled-shutdown bridge and an extended runtime application depending only on switch position and battery count. It draws power through the PSU8600's integrated connector rather than separate input terminals, and supports up to two expansion modules for additional output capacity, so it fits installations already built around the PSU8600 rack rather than a standalone 24 V bus.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960773828891,"sku":"6EP4197-8AB00-0XY0","price":475.64,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4197-8ab00-0xy0-sitop-ups8600-power-supply.png?v=1789780495","url":"https:\/\/stoklink.com\/products\/siemens-6ep4197-8ab00-0xy0-sitop-ups8600","provider":"Stoklink","version":"1.0","type":"link"}