{"product_id":"siemens-6ep4136-3ab00-0ay0-sitop-ups1600-24vdc-20a-dc-ups","title":"Siemens 6EP4136-3AB00-0AY0 SITOP UPS1600 24V DC 20A Uninterruptible Supply","description":"\u003cp\u003eThe Siemens 6EP4136-3AB00-0AY0 is a SITOP UPS1600 DC uninterruptible power supply module rated 24 V DC at 20 A, providing 21-29 V input buffering with an adjustable cut-in threshold and a rotary-switch-selectable backup time from 0.5 to 20 minutes. It delivers up to 60 A peak, runs at 97.7% efficiency with 10 W typical power loss, and carries an IP20 rating in a compact 50 x 139 x 125 mm DIN-rail enclosure weighing 0.39 kg.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP4136-3AB00-0AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21-29 V DC (24 V DC rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Normal \/ Buffering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC \/ 18.5-27 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A, 0-60 A range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharging Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1-4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCut-in Threshold, Adjustable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21-25 V DC, 7 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackup Time, Adjustable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5\/1\/2\/5\/10\/20 min or max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupplied Power, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 x 139 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.39 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF at 40 C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e408,654 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection Notes\u003c\/h2\u003e\n\u003cp\u003eThe rotary-coded backup-time switch (0.5 to 20 minutes, or maximum) sets how long the 24 V rail rides through a supply interruption before the connected battery module is exhausted, letting the same UPS1600 serve either a quick-ride-through role or a full shutdown-sequence role without reprogramming. The adjustable cut-in threshold (21-25 V in seven steps) lets it buffer only on a genuine dip rather than normal ripple from a lightly loaded 24 V supply. At 20 A rated and 60 A peak, it covers inrush from contactors and solenoids during the switchover without derating the connected battery module.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eUsed to bridge short mains interruptions for PLCs, I\/O, and drives on a 24 V DC bus in control cabinets where an orderly shutdown or ride-through is required instead of an immediate loss of power.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960772780315,"sku":"6EP4136-3AB00-0AY0","price":319.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4136-3ab00-0ay0-sitop-ups1600-24vdc-20a-dc-ups.png?v=1789678468","url":"https:\/\/stoklink.com\/products\/siemens-6ep4136-3ab00-0ay0-sitop-ups1600-24vdc-20a-dc-ups","provider":"Stoklink","version":"1.0","type":"link"}