{"product_id":"siemens-6ep4134-0gb00-0ay0-sitop-ups1100-battery-7ah","title":"Siemens 6EP4134-0GB00-0AY0 SITOP UPS1100 24V DC 7Ah Battery Module DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP4134-0GB00-0AY0 SITOP UPS1100 battery module supplies 7 Ah of maintenance-free sealed lead-acid backup capacity at 24 V DC for SITOP DC UPS modules. It delivers up to 40 A of buffering current, 120 A for 30 ms peak, and communicates battery status over its built-in interface, in an IP20, Class III enclosure rated for -15 to +50 degC operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU (MLFB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP4134-0GB00-0AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery module 7 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A rated, 40 A max in buffering mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 A for 30 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Charging Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.75 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x 25 A\/32 V blade-type fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, battery status interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 x 186 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15...+50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Life at 20 degC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 years typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecURus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eService life drops sharply with ambient temperature: rated 4 years typical at 20 degC, but only 1 year at 40 degC and 0.5 years at 50 degC, so cabinet ventilation directly affects replacement interval. The 40 A output current and 120 A\/30 ms peak rating size this module for higher-current DC UPS loads rather than small single-PLC backup, where a lower-capacity battery module would be adequate. It connects to the SITOP UPS1100 host module via screw terminals (0.5-16 mm² for +BAT\/-BAT), not a plug-in system.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eProvides ride-through backup for 24 V DC control systems, PLCs, and drives during mains interruptions in SITOP UPS1100-based installations, sized for loads that need sustained 40 A buffering current rather than momentary support.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960770715931,"sku":"6EP4134-0GB00-0AY0","price":195.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4134-0gb00-0ay0-sitop-ups1100-battery-7ah.png?v=1789714137","url":"https:\/\/stoklink.com\/products\/siemens-6ep4134-0gb00-0ay0-sitop-ups1100-battery-7ah","provider":"Stoklink","version":"1.0","type":"link"}