{"product_id":"siemens-6ep1961-2ba21-sitop-pse200u-selectivity-module","title":"Siemens 6EP1961-2BA21 SITOP PSE200U 24V DC 4x10A Power Supply Selectivity Module","description":"\u003cp\u003eThe Siemens 6EP1961-2BA21 SITOP PSE200U is a 4-channel selectivity module that splits a 24 V DC, 40 A input into four individually protected 10 A outputs with a current threshold adjustable from 3 to 10 A per channel. A common signaling contact reports overload status, and each channel switches off within about 5 seconds of exceeding its set threshold.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1961-2BA21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP PSE200U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePSE200U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC (22...30V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current per Channel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A, up to 60 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 to 10 A via potentiometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Delay, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, Typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon changeover contact, 0.1A\/24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Dimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 x 80 x 72 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF at 40 degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e540,979 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 3-10 A per-channel threshold, set individually by potentiometer, lets each of the four branch circuits trip before a fault pulls down the shared 24 V bus - choose the DIP-switch load-optimized sequential switch-on mode when downstream loads have high inrush current, such as several PLC power supplies powering up together, rather than the simultaneous mode. The 99% efficiency and 10 W typical power loss keep cabinet heat load low even with all four channels near their 10 A rating. The common signal contact wires a single alarm back to the PLC instead of monitoring four channels individually.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSelective load distribution downstream of a single 24 V DC power supply, separating PLC, HMI, I\/O, and sensor or actuator branch circuits so a short on one branch does not take down the whole 24 V bus.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960763736347,"sku":"6EP1961-2BA21","price":173.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1961-2ba21-sitop-pse200u-selectivity-module.png?v=1789678925","url":"https:\/\/stoklink.com\/products\/siemens-6ep1961-2ba21-sitop-pse200u-selectivity-module","provider":"Stoklink","version":"1.0","type":"link"}