{"product_id":"siemens-3va2325-5mn32-0aa0-3va2-3p-250a-55ka-415v-etu350m-lsi-molded-case-circuit-breaker","title":"Siemens 3VA2325-5MN32-0AA0 3VA2 3P 250A 55kA 415V ETU350M LSI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA2325-5MN32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA2 series, rated 250 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the ETU350M LSI electronic trip unit providing overload (L), short-time delay (S) and instantaneous (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA2325-5MN32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 400\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eETU350M — LSI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic (ETU)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e248 mm × 138 mm × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.664 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 250 A rated current and 55 kA breaking capacity, the 3VA2325-5MN32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The ETU350M LSI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 400 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619710103835,"sku":"3VA2325-5MN32-0AA0","price":1047.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va2325-5mn32-0aa0.webp?v=1784360394","url":"https:\/\/stoklink.com\/products\/siemens-3va2325-5mn32-0aa0-3va2-3p-250a-55ka-415v-etu350m-lsi-molded-case-circuit-breaker","provider":"Stoklink","version":"1.0","type":"link"}