{"product_id":"siemens-3va1180-5ef36-0aa0-3va1-3p-80a-55ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1180-5EF36-0AA0 3VA1 3P 80A 55kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1180-5EF36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 80 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1180-5EF36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56–80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.981 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 80 A rated current and 55 kA breaking capacity, the 3VA1180-5EF36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619694735643,"sku":"3VA1180-5EF36-0AA0","price":215.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1180-5ef36-0aa0.webp?v=1784359106","url":"https:\/\/stoklink.com\/products\/siemens-3va1180-5ef36-0aa0-3va1-3p-80a-55ka-415v-tm240-li-molded-case-circuit-breaker","provider":"Stoklink","version":"1.0","type":"link"}