{"product_id":"siemens-3va1110-5mh36-0aa0-3va1-100a-55ka-3p-mccb","title":"Siemens 3VA1110-5MH36-0AA0 3VA1 100A 55kA 3-Pole Magnetic Protection Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1110-5MH36-0AA0 is a 3-pole molded case circuit breaker from the SENTRON 3VA1 series, rated 100 A with a breaking capacity of 55 kA at 415 V AC. It provides magnetic-only protection, making it suited for motor branch circuits and starter protection applications where thermal overload is handled separately downstream.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1110-5MH36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSENTRON 3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @ 415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic only\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 × 92 × 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.006 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEAC\u003c\/li\u003e\n  \u003cli\u003eRCM\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eMagnetic-only protection in the 3VA1110-5MH36-0AA0 means the trip characteristic responds exclusively to instantaneous overcurrents — short circuits and severe fault currents — without a thermal element for sustained overload. This is the correct configuration when a separate motor overload relay or soft starter handles the thermal protection curve, keeping the MCCB focused on fault clearing at its 55 kA breaking capacity.\u003c\/p\u003e\n\u003cp\u003eAt 150 × 92 × 116 mm and 1.006 kg, the 3VA1 frame fits standard IEC switchboard busbar pitches without requiring extended depth. Three-pole configuration covers standard three-phase 415 V distribution and motor feeder circuits up to 100 A frame size.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52214665085211,"sku":"3VA1110-5MH36-0AA0","price":235.92,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/3va1110-5mh36-0aa0_d0f3c922-354d-4532-8ef7-d85e8ed01bc0.webp?v=1782491561","url":"https:\/\/stoklink.com\/products\/siemens-3va1110-5mh36-0aa0-3va1-100a-55ka-3p-mccb","provider":"Stoklink","version":"1.0","type":"link"}