{"product_id":"siemens-1ph8101-1af00-2ba2-asynchronous-motor","title":"Siemens 1PH8101-1AF00-2BA2 SIMOTICS M-1PH8 Compact Asynchronous Motor 3.7kW 1500rpm IP55","description":"\u003cp\u003eThe Siemens 1PH8101-1AF00-2BA2 is a SIMOTICS M-1PH8 compact asynchronous motor rated 3.7 kW at 1,500 rpm with 24 Nm and 12.5 A at 265 V. Output rises to 5.1 kW at 2,200 rpm across its four duty points as voltage climbs to 363 V, with current fixed at 12.5 A throughout. Forced ventilation and IP55 protection carry a Pt1000 winding temperature sensor.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1PH8101-1AF00-2BA2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMOTICS M-1PH8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuty Point 1 (1500 rpm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 kW \/ 24 Nm \/ 12.5 A \/ 265 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuty Point 2 (1750 rpm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3 kW \/ 23 Nm \/ 12.5 A \/ 304 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuty Point 3 (2000 rpm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.7 kW \/ 22 Nm \/ 12.5 A \/ 343 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuty Point 4 (2200 rpm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.1 kW \/ 22 Nm \/ 12.5 A \/ 363 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForced ventilation, air flow DE to NDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEncoder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout encoder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePt1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIM B3 (IM V5, IM V6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShaft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFitted key, half-key balancing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBearing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard, fixed bearing, vibration severity grade R\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShaft and Flange Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Entry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD-end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eTorque tapers from 24 Nm at the 265 V base point to 22 Nm at the 343-363 V field-weakening points, while current holds fixed at 12.5 A across all four duty points, so drive current sizing is set once for the full speed range. The Pt1000 sensor lets the drive trip on actual winding temperature instead of a thermal model. IP55 sealing, forced ventilation, and fixed-bearing construction at vibration severity grade R\/A suit continuous, enclosed machine-tool duty rather than intermittent or exposed installations. The half-key shaft balancing means coupling components must be selected to match that balancing convention.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eForced ventilation and IP55 sealing suit enclosed machine-tool bases rather than open, exposed mounts. Constant 12.5 A current across all duty points simplifies drive sizing for VFD-driven spindle or main-drive axes running mixed speeds between 1,500 and 2,200 rpm.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960364917019,"sku":"1PH8101-1AF00-2BA2","price":3138.85,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-1ph8101-1af00-2ba2-1ph8-asynchronous-motor.png?v=1789758281","url":"https:\/\/stoklink.com\/products\/siemens-1ph8101-1af00-2ba2-asynchronous-motor","provider":"Stoklink","version":"1.0","type":"link"}