{"product_id":"schneider-lre361-55-70a-thermal-overload-relay","title":"Schneider Electric LRE361 55-70A Easy TeSys Protect Differential Thermal Overload Relay ≤690V AC","description":"\u003cp\u003eThe Schneider Electric LRE361 is a differential thermal overload relay from the Easy TeSys Protect series, designed to provide reliable motor protection across a 55–70A current range at voltages up to 690V AC. Engineered for direct under-contactor mounting or panel\/rail installation with appropriate accessories, the LRE361 delivers precise, dependable overload detection in demanding industrial automation and control panel environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLRE361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys Protect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDifferential Thermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55–70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnder contactor; Plate (with specific accessories); Rail (with specific accessories)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e113 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity mark — approved for markets within the Eurasian Economic Union\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — electromechanical contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068:\u003c\/strong\u003e Environmental testing — general conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-1:\u003c\/strong\u003e Environmental testing — cold\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-6:\u003c\/strong\u003e Environmental testing — vibration (sinusoidal)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-7:\u003c\/strong\u003e Environmental testing — acceleration (steady state)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60255-5:\u003c\/strong\u003e Measuring relays and protection equipment — insulation coordination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60801-5:\u003c\/strong\u003e Electromagnetic compatibility for industrial process measurement and control equipment — surge immunity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU regulation compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant with EU Directive 2012\/19\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChina RoHS:\u003c\/strong\u003e Restriction of Hazardous Substances for the Chinese market\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor overload protection in industrial machinery and conveyor systems\u003c\/li\u003e\n\u003cli\u003eControl panel motor protection circuits up to 690V AC\u003c\/li\u003e\n\u003cli\u003eDirect mounting beneath compatible TeSys contactors for compact panel layouts\u003c\/li\u003e\n\u003cli\u003eAutomation systems requiring IEC-compliant thermal overload protection\u003c\/li\u003e\n\u003cli\u003eApplications demanding differential current detection to guard against phase-loss and phase imbalance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230322463003,"sku":"LRE361","price":75.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lre361-relay-690v-ac_7278ea50-52f7-4aca-9e1f-81059bac2106.jpg?v=1777166443","url":"https:\/\/stoklink.com\/products\/schneider-lre361-55-70a-thermal-overload-relay","provider":"Stoklink","version":"1.0","type":"link"}