{"product_id":"schneider-gv3l50-gv3p-3p-50a-50ka-tesys-deca-circuit-breaker","title":"Schneider Electric GV3L50 GV3P 3P 50A 50kA 690V TeSys Deca Manual Motor Starter Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric GV3L50 (model GV3P) is a 3-pole 50A manual motor starter and circuit breaker from the TeSys GV3 \/ TeSys Deca series, rated for 690V AC 50\/60 Hz with an exceptional breaking capacity of 50 kA at 400\/415V AC. Designed for motor protection in industrial control panels, the GV3L50 provides thermal-magnetic protection for motors up to 22 kW at 400\/415V, 30 kW at 500V, and 45 kW at 690V, making it a versatile solution across a wide range of drive applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV3L50\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys GV3 \/ TeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual Motor Starter \/ Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400\/415V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power @ 400\/415V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power @ 500V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power @ 690V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm symmetrical DIN rail; Panel screwed with 3 × M4 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e132 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e136 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.96 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389119405454\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN\/IEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN\/IEC 60947-4-1:\u003c\/strong\u003e Low-voltage switchgear — electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No 60947-4-1:\u003c\/strong\u003e Canadian standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIECEE CB Scheme:\u003c\/strong\u003e International mutual recognition of safety test results\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity mark\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping approved\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLR (Lloyd's Register of Shipping):\u003c\/strong\u003e Marine type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNV-GL:\u003c\/strong\u003e Det Norske Veritas – Germanischer Lloyd marine approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas marine type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed mark for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChina RoHS:\u003c\/strong\u003e Chinese restriction of hazardous substances compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP rating)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-6:\u003c\/strong\u003e Environmental testing — vibration sinusoidal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60695-2-1:\u003c\/strong\u003e Fire hazard testing — glow-wire method\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect-on-line motor starting and protection for motors up to 45 kW\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels in manufacturing, process automation, and HVAC\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore electrical installations (ABS, LR, DNV-GL, BV approved)\u003c\/li\u003e\n  \u003cli\u003eOEM machine builders requiring IEC and UL dual-certified protection devices\u003c\/li\u003e\n  \u003cli\u003eDIN rail or panel-mounted motor feeder circuits in MCC (Motor Control Centers)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230501605659,"sku":"GV3L50","price":168.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv3l50-starter-circuit-breaker_3486de7c-889a-4840-a6c6-e9a4a6114455.jpg?v=1777165416","url":"https:\/\/stoklink.com\/products\/schneider-gv3l50-gv3p-3p-50a-50ka-tesys-deca-circuit-breaker","provider":"Stoklink","version":"1.0","type":"link"}