{"product_id":"schneider-electric-xpsmcmdi1600-safe-input-module","title":"Schneider Electric XPSMCMDI1600 Modicon MCM Safe Input Expansion Module 16 Inputs Screw Terminals Safety PLC","description":"\u003cp\u003eThe Schneider Electric XPSMCMDI1600 is a Modicon MCM safe input expansion module with 16 isolated digital safety inputs and 4 PNP test outputs, wired through captive screw-clamp terminals at 24 V DC. It connects to an XPSMCM safety controller over the backplane expansion bus to add input capacity and cannot operate stand-alone. Each input has configurable filtering and delay for functions such as emergency stop and guard monitoring.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eXPSMCMDI1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480748622\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003ePreventa Safety automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Short Name\u003c\/td\u003e\n\u003ctd\u003eXPSMCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafe input expansion module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (-20...+20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e16 digital safety inputs (isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e4 test outputs for line control (PNP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Level\u003c\/td\u003e\n\u003ctd\u003eCategory 4 \/ PL e (ISO 13849-1), SIL 3 (IEC 61508), SILCL 3 (IEC 62061)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Reliability Data\u003c\/td\u003e\n\u003ctd\u003ePFHd 7.09E-9 1\/h, DC \u0026gt;99%, MTTFd \u0026lt;100 years (high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connection\u003c\/td\u003e\n\u003ctd\u003eBackplane expansion bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eOmega 35 mm DIN rail (EN 50022)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e114.5 x 99 x 22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e20 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eTÜV\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eIEC 61800-5-1\u003c\/li\u003e\n\u003cli\u003eIEC 61508\u003c\/li\u003e\n\u003cli\u003eISO 13849-1\u003c\/li\u003e\n\u003cli\u003eIEC 62061\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe XPSMCMDI1600 adds 16 isolated safe digital inputs to an XPSMCM controller over the backplane bus; it expands an existing Modicon MCM safety controller CPU and cannot run stand-alone. Pick this module over the 8-input variant when a cell has more than 8 separate safety-input devices to wire into one module slot, or the 12-input safety-mat variant when those inputs are specifically 4-wire safety mats. Isolated inputs keep each sensor's return path independent, which simplifies fault tracing on a module carrying this many field connections, and the 2 node-address LEDs on the front face confirm backplane addressing at a glance during commissioning.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54074334118171,"sku":"XPSMCMDI1600","price":524.95,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-xpsmcmdi1600-modicon-mcm-input-module.jpg?v=1790839133","url":"https:\/\/stoklink.com\/products\/schneider-electric-xpsmcmdi1600-safe-input-module","provider":"Stoklink","version":"1.0","type":"link"}