{"product_id":"schneider-electric-xpsmcmco0000co-canopen-module","title":"Schneider Electric XPSMCMCO0000CO Modicon MCM CANopen Diagnostic Expansion Module Screw Terminals Safety PLC","description":"\u003cp\u003eThe Schneider Electric XPSMCMCO0000CO is a Modicon MCM non-safe communication module that adds one CANopen port, via a male Sub-D 9 connector, to an XPSMCM safety controller for remote diagnostics. It connects over the backplane expansion connector and cannot operate stand-alone, reporting controller status to a CANopen network at rates from 10 kbit\/s to 1 Mbit\/s without an additional gateway.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eXPSMCMCO0000CO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480748349\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon MCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Short Name\u003c\/td\u003e\n\u003ctd\u003eXPSMCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eNon-safe communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (-20...+20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMale Sub-D 9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Ports\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eCANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e10 kbit\/s to 1 Mbit\/s, autodetected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e0.125 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cable Distance\u003c\/td\u003e\n\u003ctd\u003e25-2500 m, depending on transmission rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eOmega 35 mm DIN rail (EN 50022)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e114.5 x 99 x 22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e20 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eTÜV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe XPSMCMCO0000CO is a non-safe diagnostic module: it reports the connected XPSMCM safety controller's status over CANopen for remote monitoring but carries none of the safety function itself, so it expands an existing Modicon MCM safety controller CPU and cannot run stand-alone. Choose it over the EtherCAT, EtherNet\/IP or Modbus TCP\/IP diagnostic variants when the plant's existing fieldbus is CANopen, or choose the RS485 safe communication module instead when the link needs to carry safe communication rather than non-safe diagnostics.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe XPSMCMCO0000CO fits cells where a plant-wide CANopen SCADA or PLC network already polls other field devices, letting the same network pick up the safety controller's run\/error status alongside drive and I\/O diagnostics instead of running a separate monitoring cable back to the control room. The module relays status only and plays no part in the controller's own safety decision.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54074306330907,"sku":"XPSMCMCO0000CO","price":700.15,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-xpsmcmco0000co-modicon-mcm-canopen-module.jpg?v=1790839029","url":"https:\/\/stoklink.com\/products\/schneider-electric-xpsmcmco0000co-canopen-module","provider":"Stoklink","version":"1.0","type":"link"}