{"product_id":"schneider-electric-tr25d3r2004tpe-transferpact","title":"Schneider Electric TR25D3R2004TPE TransferPacT Remotely Operated 3P 200 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR25D3R2004TPE is a 3-pole, 200 A TransferPacT automatic transfer switch built on the 250 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 30 kA making capacity and a 10 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR25D3R2004TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 8 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA for 0.5 s (15 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 35 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 370 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR25D3R2004TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 3P version switches the three phase conductors, so it is the lower-cost choice for 3-wire distribution. On the 250 A frame, the 200 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 10 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078639735067,"sku":"TR25D3R2004TPE","price":1485.37,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr25d3r2004tpe-transferpact-automatic-transfer-switch.jpg?v=1790904627","url":"https:\/\/stoklink.com\/products\/schneider-electric-tr25d3r2004tpe-transferpact","provider":"Stoklink","version":"1.0","type":"link"}