{"product_id":"schneider-electric-tm3saf5r","title":"Schneider Electric TM3SAF5R Modicon TM3 Safety TM3SAF Cat 4 PL e SILCL 3 Safety Relay","description":"\u003cp\u003eThe Schneider Electric TM3SAF5R is a Modicon TM3 Safety expansion module (device short name TM3SAF) that adds one configurable safety function, emergency stop or movable-guard monitoring, to Modicon M221, M241 and M251 controllers, reaching PL e \/ Category 4 per ISO 13849-1 and SILCL 3 per IEC 62061 on a 24 V DC supply.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM3SAF5R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606485392998\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon TM3 Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Short Name\u003c\/td\u003e\n\u003ctd\u003eTM3SAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafety module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module Application\u003c\/td\u003e\n\u003ctd\u003eEmergency stop and switch monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction of Module\u003c\/td\u003e\n\u003ctd\u003eEmergency stop monitoring (1- or 2-channel wiring) or movable guard monitoring with 2 switches and automatic start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Level\u003c\/td\u003e\n\u003ctd\u003ePL e \/ Category 4 (ISO 13849-1), SILCL 3 (IEC 62061), SIL 3 (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Coverage\u003c\/td\u003e\n\u003ctd\u003eDC = 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFHd\u003c\/td\u003e\n\u003ctd\u003e5E-9 \/h at 1 operation\/hour, DC-13 24V DC less than 4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTTFd\u003c\/td\u003e\n\u003ctd\u003e500 years at 1 operation\/hour, DC-13 24V DC less than 4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage [Us]\u003c\/td\u003e\n\u003ctd\u003e24 V DC -15...+20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.6 W at 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e3 NO relay, instantaneous opening, potential free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e4 A at 24V DC-13 \/ 360 VA holding AC-15 B300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Thermal Current\u003c\/td\u003e\n\u003ctd\u003e6 A per relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time on Input Open\u003c\/td\u003e\n\u003ctd\u003e40 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Signalling\u003c\/td\u003e\n\u003ctd\u003e8 LEDs (green\/red)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eScrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eTH35-7.5 \/ TH35-15 DIN rail, wall mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e43.7 x 73 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.19 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eTÜV\u003c\/li\u003e\n\u003cli\u003eUL 61010-2-201\u003c\/li\u003e\n\u003cli\u003eCSA 61010-2-201\u003c\/li\u003e\n\u003cli\u003eIEC 60947-1\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eIEC 60204-1\u003c\/li\u003e\n\u003cli\u003eISO 13850\u003c\/li\u003e\n\u003cli\u003eEN 1088\/ISO 14119\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eChoose the TM3SAF5R when the risk assessment calls for PL e \/ Category 4 and SILCL 3, the highest single-function safety level in the TM3 Safety range. The TM3SAC5R covers the same emergency-stop and guard-monitoring functions at the lower Cat 3 \/ PL d \/ SILCL 2 level, while the TM3SAK6R adds sensing-mat, light-curtain and proximity-sensor monitoring at the same Cat 4 \/ PL e rating.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54072486101275,"sku":"TM3SAF5R","price":399.33,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm3saf5r-safety-module.jpg?v=1790802872","url":"https:\/\/stoklink.com\/products\/schneider-electric-tm3saf5r","provider":"Stoklink","version":"1.0","type":"link"}