{"product_id":"schneider-electric-sr3xt101fu-io-extension-module","title":"Schneider Electric SR3XT101FU Zelio Logic SR3 10 I\/O Extension Module 100-240 V AC PLC I\/O Module","description":"\u003cp\u003eThe Schneider Electric SR3XT101FU is a discrete I\/O extension module for the Zelio Logic SR3 range, adding 10 I\/O (6 discrete inputs, 4 relay outputs) at 100–240 V AC to a base smart relay. It mounts on the same DIN rail as the base unit to expand the I\/O count of larger automation systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSR3XT101FU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZelio Logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110550139\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscrete I\/O extension module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85–264 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6, 100–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 relay, NO contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 A for all 4 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV (EN\/IEC 60947-1, EN\/IEC 60664-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections – Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminals, 0.2–2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII (IEC 60664-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (terminal block) \/ IP40 (front panel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Air Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20…40 °C (non-ventilated) \/ -20…55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Air Temperature, Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eGOST\u003c\/li\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eC-tick\u003c\/li\u003e\n\u003cli\u003eIEC 61000-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 61000-4-3\u003c\/li\u003e\n\u003cli\u003eIEC 61000-4-4\u003c\/li\u003e\n\u003cli\u003eIEC 61000-4-5\u003c\/li\u003e\n\u003cli\u003eIEC 61000-4-6\u003c\/li\u003e\n\u003cli\u003eIEC 61000-4-11\u003c\/li\u003e\n\u003cli\u003eIEC 61000-4-12\u003c\/li\u003e\n\u003cli\u003eIEC 60068-2-6\u003c\/li\u003e\n\u003cli\u003eIEC 60068-2-27\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe SR3XT101FU runs its 6 inputs directly from 100–240 V AC, so it extends an AC-supplied FU base unit without a separate 24 V DC source — its input debounce time (50–255 ms) is slower than the DC-supplied SR3XT101BD, which is a secondary factor on fast counting inputs. Both add 4 relay outputs rated 8 A; use the smaller SR3XT61FU when only 4 extra inputs and 2 extra outputs are needed.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54072635982107,"sku":"SR3XT101FU","price":104.66,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-sr3xt101fu-io-extension-module.jpg?v=1790806745","url":"https:\/\/stoklink.com\/products\/schneider-electric-sr3xt101fu-io-extension-module","provider":"Stoklink","version":"1.0","type":"link"}