{"product_id":"schneider-electric-rm35ja32mw-current-control-relay","title":"Schneider Electric RM35JA32MW Harmony RM35JA 5A 2CO 0.15-15A 24-240V AC\/DC Control Relay","description":"\u003cp\u003eThe Schneider Electric RM35JA32MW is a Harmony RM35JA current control relay that detects overcurrent or undercurrent on single-phase circuits from 150 mA to 15 A. It switches 2 C\/O contacts rated 5 A from a universal 24-240 V AC\/DC 50\/60 Hz supply and mounts on 35 mm DIN rail. Threshold and hysteresis are field-adjustable.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eRM35JA32MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eHarmony Control Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eRM35JA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCurrent control relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitored Parameter\u003c\/td\u003e\n\u003ctd\u003eOvercurrent or undercurrent detection (single-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContacts\u003c\/td\u003e\n\u003ctd\u003e2 C\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e150 mA...15 A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage (Us)\u003c\/td\u003e\n\u003ctd\u003e24...240 V AC\/DC 50\/60 Hz, non self-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e20.4...264 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Delay\u003c\/td\u003e\n\u003ctd\u003eAdjustable 0.3...30 s (fault, Tt) \/ 1...20 s (startup inhibition, Ti)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Capacity\u003c\/td\u003e\n\u003ctd\u003e1250 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Current\u003c\/td\u003e\n\u003ctd\u003e5 A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHysteresis\u003c\/td\u003e\n\u003ctd\u003e5...50% of threshold setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThreshold Setting\u003c\/td\u003e\n\u003ctd\u003e10...100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (terminals) \/ IP30 (casing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003e35 mm symmetrical DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eGOST\u003c\/li\u003e\n\u003cli\u003eC-tick\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eIEC 60255-6\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRM35JA32MW's 150 mA-15 A measurement window spans light-load to full-load single-phase currents, so the same part covers small fan motors and larger single-phase pumps by adjusting the threshold (10-100%) and hysteresis (5-50%) rather than swapping relays. Its 2 C\/O output, versus RM35BA10's single contact, lets one contact drive an alarm circuit while the other trips the load contactor. The startup inhibition delay (1-20 s) rides through motor inrush before undercurrent tripping is armed.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229836939547,"sku":"RM35JA32MW","price":159.54,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-rm35ja32mw-rm35ja-control-relay.jpg?v=1790282829","url":"https:\/\/stoklink.com\/products\/schneider-electric-rm35ja32mw-current-control-relay","provider":"Stoklink","version":"1.0","type":"link"}