{"product_id":"schneider-electric-metsepm3255-powerlogic-pm3255-power-meter","title":"Schneider Electric METSEPM3255 PowerLogic PM3255 Power Meter Class 0.5S DIN Mount 2DI 2DO RS485 Power Meter","description":"\u003cp\u003eThe Schneider Electric METSEPM3255 is a PowerLogic PM3255 DIN-rail power meter, measuring energy, active and reactive power, voltage, current, frequency, power factor, and harmonics up to the 15th order with Class 0.5S accuracy to IEC 62053-22. It reads out on a backlit 128 x 96 pixel LCD, communicates over RS485 Modbus, and adds 2 digital inputs plus 2 static digital outputs with 512 kB of onboard logging.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eMETSEPM3255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003ePowerLogic PM3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003ePower meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy class\u003c\/td\u003e\n\u003ctd\u003eClass 0.5S active energy IEC 62053-22, Class 1 active energy IEC 62053-21, Class 2 reactive energy IEC 62053-23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd\u003eCurrent 0.3 % (0.5...6 A), voltage 0.3 % (50...330 V \/ 80...570 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e100...277 V AC, 173...480 V AC, or 100...300 V DC, 45...65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (In)\u003c\/td\u003e\n\u003ctd\u003e1 A \/ 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork frequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of network\u003c\/td\u003e\n\u003ctd\u003e1P+N, 3P, 3P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower quality analysis\u003c\/td\u003e\n\u003ctd\u003eUp to the 15th harmonic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling rate\u003c\/td\u003e\n\u003ctd\u003e32 samples\/cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay type\u003c\/td\u003e\n\u003ctd\u003eBacklit LCD, 128 x 96 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eModbus RTU\/ASCII, RS485, 9.6-38.4 kbaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e2 digital, 0...4 mA, 11...40 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e2 digital (static)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory capacity\u003c\/td\u003e\n\u003ctd\u003e512 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording\u003c\/td\u003e\n\u003ctd\u003eEnergy consumption logs, power logs, time stamping, 15 alarms, min\/max of instantaneous values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode\u003c\/td\u003e\n\u003ctd\u003eClip-on, DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e90 x 95 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eIEC 61557-12\u003c\/li\u003e\n\u003cli\u003eIEC 62053-21\u003c\/li\u003e\n\u003cli\u003eIEC 62053-22\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe METSEPM3255 is the fullest DIN-rail PM3000 variant in this batch, adding 2 digital inputs, 2 digital outputs, and 512 kB of onboard power and energy logging to the RS485 link the PM3250 already has. Choose it over the PM3250 whenever the installation needs to capture a breaker status or trip signal locally alongside remote Modbus polling, or needs the extra memory for on-meter trend logs.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080902496539,"sku":"METSEPM3255","price":193.21,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-metsepm3255-powerlogic-pm3255-power-meter.jpg?v=1790935977","url":"https:\/\/stoklink.com\/products\/schneider-electric-metsepm3255-powerlogic-pm3255-power-meter","provider":"Stoklink","version":"1.0","type":"link"}