{"product_id":"schneider-electric-lxd1m7-contactor-coil","title":"Schneider Electric LXD1M7 TeSys LXD1 220 V AC Contactor Coil","description":"\u003cp\u003eThe Schneider Electric LXD1M7 is a TeSys LXD1 replacement contactor coil rated 220 V AC 50\/60 Hz, compatible with the LC1D09 through LC1D38 and LC1DT20 through LC1DT40 contactor range. It draws 70 VA inrush and 7-7.5 VA hold-in power, with a coil resistance of 515.4 Ohm and 18 H inductance in the closed-circuit state, and has no built-in suppressor module.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLXD1M7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor Coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLXD1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage [Uc]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAverage Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e515.4 Ohm (at 20 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInductance (closed circuit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D09...D38, LC1DT20...DT40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout built-in suppressor module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDrop-out 0.3-0.6 Uc; operational 0.8-1.1 Uc (50 Hz) \/ 0.85-1.1 Uc (60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 VA (50\/60 Hz, cos phi 0.75, at 20 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHold-in Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-7.5 VA (50\/60 Hz, cos phi 0.3, at 20 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-3 W (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5...60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.07 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110467895\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is a service-replacement coil, not a complete contactor: it fits the LC1D09 to LC1D38 and LC1DT20 to LC1DT40 frame sizes, so confirm the existing contactor's reference falls in that range before ordering. It has no built-in suppressor module, unlike the low-consumption BL-suffix contactor coils, so any external surge-suppression wiring on the original coil circuit should stay in place.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed to replace a failed or mismatched 220 V AC coil in an existing TeSys LC1D or LC1DT contactor without replacing the full contactor body.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230426108187,"sku":"LXD1M7","price":11.26,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lxd1m7-tesys-contactor-coil.jpg?v=1790285815","url":"https:\/\/stoklink.com\/products\/schneider-electric-lxd1m7-contactor-coil","provider":"Stoklink","version":"1.0","type":"link"}