{"product_id":"schneider-electric-lv563552","title":"Schneider Electric LV563552 EasyPact CVS630N 3P 500 A 50 kA MA Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric LV563552 is a 500 A EasyPact CVS630N moulded case circuit breaker for low-voltage distribution. Its MA trip unit gives magnetic-only short-circuit protection with an adjustable instantaneous threshold, and the 3-pole, 3D frame breaks 50 kA at 380\/415 V AC under IEC 60947-2.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Reference\u003c\/td\u003e\n\u003ctd\u003eLV563552\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eEasyPact CVS630N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice application\u003c\/td\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtected poles\u003c\/td\u003e\n\u003ctd\u003e3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current [In]\u003c\/td\u003e\n\u003ctd\u003e500 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated impulse withstand voltage [Uimp]\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity code\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity [Icu]\u003c\/td\u003e\n\u003ctd\u003e70 kA at 220\/240 V AC, 50 kA at 380\/415 V AC, 42 kA at 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity [Ics]\u003c\/td\u003e\n\u003ctd\u003e70 kA at 220\/240 V AC, 50 kA at 380\/415 V AC, 32 kA at 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eMA, magnetic-only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit rating\u003c\/td\u003e\n\u003ctd\u003e500 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection functions\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protection (magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstantaneous pickup adjustment [Ii]\u003c\/td\u003e\n\u003ctd\u003e6...13 x In, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact position indicator\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFixed, backplate support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eFront (upside and downside), 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e140 x 255 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e5.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical shock protection\u003c\/td\u003e\n\u003ctd\u003eClass II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C operation, -50...85 °C storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC\u003c\/li\u003e\n\u003cli\u003eGOST\u003c\/li\u003e\n\u003cli\u003eEN 60947-2\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eLV563552 uses a fixed-thermal, magnetic-only MA trip unit rather than an adjustable electronic unit, so overload protection for the 500 A rating is set at the factory and only the instantaneous threshold (6...13 x In) is field-adjustable -- a simpler, lower-cost choice where the motor or feeder's steady-state current is already known. Choose the N-frame breaking class (50 kA at 380\/415 V) over a lower class whenever downstream prospective fault current exceeds a 36 kA threshold.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229420589339,"sku":"LV563552","price":688.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv563552-cvs630n-moulded-case-circuit-breaker.jpg?v=1790868106","url":"https:\/\/stoklink.com\/products\/schneider-electric-lv563552","provider":"Stoklink","version":"1.0","type":"link"}