{"product_id":"schneider-electric-lv563511","title":"Schneider Electric LV563511 EasyPact CVS630N 4P 630 A 50 kA ETS 2.3 Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric LV563511 is a 630 A EasyPact CVS630N moulded case circuit breaker for low-voltage distribution. Its ETS 2.3 electronic trip unit gives adjustable long-time and short-time overload protection with a fixed instantaneous stage (LSoI), and the 4-pole, 4D | 3D+N\/2 | 3D frame breaks 50 kA at 380\/415 V AC under IEC 60947-2.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Reference\u003c\/td\u003e\n\u003ctd\u003eLV563511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eEasyPact CVS630N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice application\u003c\/td\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtected poles\u003c\/td\u003e\n\u003ctd\u003e4D | 3D+N\/2 | 3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated operational voltage [Ue]\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current [In]\u003c\/td\u003e\n\u003ctd\u003e630 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated impulse withstand voltage [Uimp]\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity code\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity [Icu]\u003c\/td\u003e\n\u003ctd\u003e70 kA at 220\/240 V AC, 50 kA at 380\/415 V AC, 42 kA at 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity [Ics]\u003c\/td\u003e\n\u003ctd\u003e70 kA at 220\/240 V AC, 50 kA at 380\/415 V AC, 32 kA at 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eETS 2.3, electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit rating\u003c\/td\u003e\n\u003ctd\u003e630 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection functions\u003c\/td\u003e\n\u003ctd\u003eLSoI (long-time overload, short-time delay, fixed instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeutral protection setting\u003c\/td\u003e\n\u003ctd\u003e1 x Ir (4D) or 0.5 x Ir (3D+N\/2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-time pickup adjustment [Ir]\u003c\/td\u003e\n\u003ctd\u003e9 settings, 250...630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-time pickup adjustment [Isd]\u003c\/td\u003e\n\u003ctd\u003e1.5...10 x Ir, adjustable, 9 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstantaneous pickup [Ii]\u003c\/td\u003e\n\u003ctd\u003e11 x In, fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal memory\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFixed, backplate support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eFront (upside and downside), 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e185 x 255 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e7.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical shock protection\u003c\/td\u003e\n\u003ctd\u003eClass II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C operation, -50...85 °C storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC\u003c\/li\u003e\n\u003cli\u003eGOST\u003c\/li\u003e\n\u003cli\u003eEN 60947-2\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe ETS 2.3 trip unit on LV563511 adds a short-time delay stage (the 'S' in LSoI) ahead of the fixed instantaneous trip, so it coordinates selectively with downstream breakers instead of tripping instantly on every fault -- useful on an incomer feeding several sub-boards. The 4-pole, 4D | 3D+N\/2 | 3D frame lets the neutral protection be set to 1 x Ir for a fully monitored neutral or 0.5 x Ir where the neutral only needs half coverage; pick a lower-breaking N-code sibling only if upstream fault current stays below 50 kA at 380\/415 V.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229420065051,"sku":"LV563511","price":1100.81,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv563511-cvs630n-moulded-case-circuit-breaker.jpg?v=1790868106","url":"https:\/\/stoklink.com\/products\/schneider-electric-lv563511","provider":"Stoklink","version":"1.0","type":"link"}