{"product_id":"schneider-electric-lv510311-easypact-cvs100b-mccb","title":"Schneider Electric LV510311 EasyPact CVS100B 4P 25 A 25 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric LV510311 is a 4-pole EasyPact CVS100B moulded case circuit breaker rated 25 A, with a breaking capacity of 25 kA at 380\/415 V AC. It uses a TM-D thermal-magnetic trip unit, combining adjustable thermal overload protection with a fixed magnetic short-circuit trip, and mounts as a fixed, backplate-mounted device for distribution applications up to 25 A.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV510311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyPact CVS100...250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCVS100B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (3D protected, neutral position left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kA at 220\/240 V AC, 25 kA at 380\/415 V AC, 20 kA at 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Rated service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kA at 220\/240 V AC, 25 kA at 380\/415 V AC, 15 kA at 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D (thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload protection (thermal), short-circuit protection (magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal protection adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5…25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous pick-up [Ii]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting \/ Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, backplate mounted, front\/front screw connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical shock protection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass II (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC\u003c\/li\u003e\n\u003cli\u003eGOST\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-D trip unit on the LV510311 pairs an adjustable thermal overload stage (17.5–25 A) with a fixed magnetic instantaneous trip at 300 A, so the overload threshold can be tuned to the connected load while the short-circuit threshold stays fixed. The 4-pole version adds a protected neutral pole. In the CVS100B frame, 25 kA at 380\/415 V AC covers general distribution circuits with moderate fault levels; move to the CVS100F (36 kA) code if the prospective fault current at the installation point is higher.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54076250325275,"sku":"LV510311","price":129.65,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv510311-easypact-cvs100b-mccb.jpg?v=1790868226","url":"https:\/\/stoklink.com\/products\/schneider-electric-lv510311-easypact-cvs100b-mccb","provider":"Stoklink","version":"1.0","type":"link"}