{"product_id":"schneider-electric-lv434220-nsx-bscm-modbus","title":"Schneider Electric LV434220 ComPacT NSX BSCM Modbus SL\/ULP Communication Module Circuit Breaker Accessory","description":"\u003cp\u003eThe Schneider Electric LV434220 BSCM Modbus SL\/ULP is a breaker status communication module for ComPacT NSX100 to NSX630 circuit breakers, powered at 24 V DC. Installed inside the breaker behind the front cover, it converts the device's analog indication contacts (O\/F, SD, SDE) into digital status, control and measurement data for Modbus and ULP communication.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV434220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX100...250 and NSX400...630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX100, NSX160, NSX250, NSX400, NSX630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl circuit breaker, get breaking status, Modbus-SL gateway for connected devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication network\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus, Modbus Serial Line slave, 9.6-38.4 kbauds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBy clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC +\/- 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 mA at 24 V DC, room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.96 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-in connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34 x 28 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCISPR 32\u003c\/li\u003e\n\u003cli\u003eIEC 61000-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 61000-4-3\u003c\/li\u003e\n\u003cli\u003eIEC 61000-4-4\u003c\/li\u003e\n\u003cli\u003eIEC 61000-4-5\u003c\/li\u003e\n\u003cli\u003eIEC 61000-4-6\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe BSCM gives native Modbus-SL and ULP connectivity and an onboard memory for maintenance indicators, which a bare indication-contact wiring loom cannot provide; use it where the breaker needs to report status and be controlled remotely rather than just signal locally via dry contacts. Daisy-chaining several breakers' BSCM modules requires the separate Modbus SL Hub, and reaching Ethernet or Modbus masters requires an IFE or IFM interface module connected via the NSX cord terminal block in ULP mode.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54076455256347,"sku":"LV434220","price":240.78,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv434220-nsx-bscm-modbus-sl-ulp.jpg?v=1790869491","url":"https:\/\/stoklink.com\/products\/schneider-electric-lv434220-nsx-bscm-modbus","provider":"Stoklink","version":"1.0","type":"link"}