{"product_id":"schneider-electric-lucb32es-tesys-ultra-control-unit","title":"Schneider Electric LUCB32ES TeSys Ultra Advanced Control Unit 8-32 A 48-72 V AC\/DC Motor Starter Module","description":"\u003cp\u003eThe Schneider Electric LUCB32ES is a TeSys Ultra advanced control unit that plugs into an LUB320 or LUB380 power base to form a complete TeSys U starter-controller for 3-phase motors up to 15 kW at 400 V. It covers an adjustable rated current Ir of 8-32 A with class 10 overload tripping, and runs on 48 V AC \/ 48-72 V DC control power.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUCB32ES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Ultra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdvanced control unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Power Bases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUB320, LUB380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Motor Current Adjustment Range (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (690 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Overload Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping Threshold (Overcurrent)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.2 x Ir +\/- 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload, short-circuit, phase failure\/imbalance, earth fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 V AC \/ 48-72 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReset\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFixing Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-in (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 front panel \/ IP40 outside connection zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66 x 45 x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eASEFA\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eMarine\u003c\/li\u003e\n\u003cli\u003eEN 60947-6-2\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 48-72 V AC\/DC control voltage sets this unit apart from the 110-240 V LUCB32FU sibling, matching panels built on a 48 V or 24-72 V control bus rather than a standard 110\/240 V transformer tap. Its thermal overload alarm needs an additional function module ordered separately for diagnostics, unlike the higher-voltage siblings that support the LUFDA\/LULC alarm modules directly; pick the 110-240 V coil version instead when the panel already runs that control voltage.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003e3-phase motor starters up to 15 kW at 400 V in panels standardized on a 48 V DC or AC control bus, common in battery-backed or low-voltage-control industrial machinery.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078522589467,"sku":"LUCB32ES","price":128.11,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lucb32es-tesys-ultra-control-unit.jpg?v=1790901610","url":"https:\/\/stoklink.com\/products\/schneider-electric-lucb32es-tesys-ultra-control-unit","provider":"Stoklink","version":"1.0","type":"link"}