{"product_id":"schneider-electric-ltmtctv100t-tesys-tera-sensor-module","title":"Schneider Electric LTMTCTV100T TeSys Tera CTVT Horizontal 10-100 A Sensor Module Automation Component","description":"\u003cp\u003eThe Schneider Electric LTMTCTV100T is a TeSys Tera horizontal-mount sensor module measuring 10-100 A current and phase-to-phase voltage for a TeSys Tera motor management system, with a 100 kA short-circuit withstand rating and an integral input for ground-fault CT.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLTMTCTV100T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Tera\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLTMT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Tera motor controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10-100 A at 60...690 V AC, 45...65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV (current\/voltage measurement circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit withstand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 3% voltage | +\/- 3% current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent sensor | Voltage sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e74.7 x 110.3 x 60.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003ecUL\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\/CSA 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eMatch the sensor's 10-100 A current range to the motor's full-load current rather than to the frame size of the breaker or contactor ahead of it; choose a CTV-coded module over the plain CT when the application also needs phase voltage, undervoltage\/overvoltage or power-factor monitoring from the TeSys Tera controller.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078446338331,"sku":"LTMTCTV100T","price":230.05,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ltmtctv100t-tesys-tera-sensor-module.jpg?v=1790900399","url":"https:\/\/stoklink.com\/products\/schneider-electric-ltmtctv100t-tesys-tera-sensor-module","provider":"Stoklink","version":"1.0","type":"link"}