{"product_id":"schneider-electric-lc1f1700m7-tesys-f-contactor","title":"Schneider Electric LC1F1700M7 TeSys F Contactor 3P 3NO AC-1 1700 A 220 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1F1700M7 is a 3-pole TeSys F contactor rated 1700 A AC-1 at up to 1000 V AC, built for switching large non-inductive loads such as resistive heater banks, transformer primaries and bus-tie applications. It carries a 220 V AC coil and bolted bus-bar power terminals, with a 2550 A rated breaking capacity and a 10 kA short-time withstand for 10 s.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1F1700M7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistive load (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1700 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 V AC, 40–400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2550 A (IEC 60947-4-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA for 10 s \/ 3 kA for 10 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1600 A gG at ≤ 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 W (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolted bar, 3 cables, busbar 100 x 5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque (power circuit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 cyc\/h at 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e332 x 438 x 238.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5...40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eIEC 60947-1\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN 60947-1\u003c\/li\u003e\n\u003cli\u003eEN 60947-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-4-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 1700 A AC-1, the LC1F1700M7 is sized for resistive and non-inductive duty, not motor starting — the 2550 A breaking capacity and bolted bar terminals suit fixed heater-bank or bus-tie installations where the load current is steady rather than inrush-heavy. The 220 V AC coil draws 36 VA holding power, so panel designers standardising on a single 220 V control transformer across a switchboard can use the same coil spec on the lower-current TeSys F frames. Where the application needs higher continuous current in the same bolted-bar frame, the next size up in the TeSys F range carries the identical 332 x 438 mm footprint and mounting pattern.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230431744283,"sku":"LC1F1700M7","price":5002.3,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1f1700m7-tesys-f-contactor.jpg?v=1790900883","url":"https:\/\/stoklink.com\/products\/schneider-electric-lc1f1700m7-tesys-f-contactor","provider":"Stoklink","version":"1.0","type":"link"}