{"product_id":"schneider-electric-lc1dt25bd-tesys-deca-contactor","title":"Schneider Electric LC1DT25BD TeSys Deca Contactor 4P 4NO AC-1 25 A 24 V DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1DT25BD is a compact 4-pole TeSys Deca contactor rated 25 A AC-1 for non-inductive and resistive loads up to 440 V. It runs on a 24 V DC coil with a built-in bidirectional peak-limiting diode suppressor and includes a 1 NO + 1 NC auxiliary block with a mirror-certified NC contact.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1DT25BD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P, 4 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at \u0026lt;= 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting diode suppressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC built-in, NC mirror certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Time Withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 A \/ 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20, front face\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cycles\/h at 60 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or screw\/plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 x 45 x 99 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.365 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eLROS\u003c\/li\u003e\n\u003cli\u003eRINA\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eGOST\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 14\u003c\/li\u003e\n\u003cli\u003eEN 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN 60947-5-1\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eIEC 60335-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 24 V DC coil with built-in suppressor diode fits panels already wired on a DC control bus, and the integrated 1 NO + 1 NC block covers interlocking without a separate contact block. Pick this 25 A frame over the LC1DT20 sibling when the resistive load runs slightly above 20 A; choose an AC-coil sibling instead when the panel runs on a standard AC control transformer.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eDC-control panels, battery-backed switchgear, and compact marine or shore-based distribution boards covered by the DNV\/GL\/LROS\/RINA\/BV society approvals. The 45 mm frame also fits densely populated control cabinets where several contactors share a single DIN rail segment.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230401564955,"sku":"LC1DT25BD","price":57.88,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1dt25bd-tesys-deca-contactor.jpg?v=1790901697","url":"https:\/\/stoklink.com\/products\/schneider-electric-lc1dt25bd-tesys-deca-contactor","provider":"Stoklink","version":"1.0","type":"link"}