{"product_id":"schneider-electric-lc1dt25b7-tesys-deca-contactor","title":"Schneider Electric LC1DT25B7 TeSys Deca Contactor 4P 4NO AC-1 25 A 24 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1DT25B7 is a TeSys Deca 4-pole (4NO) contactor rated 25 A AC-1 for non-inductive loads at up to 690 V. It takes a 24 V 50\/60 Hz AC coil, a low-voltage control standard on machine panels, and 1NO+1NC mirror-certified auxiliary contacts come built in. Screw clamp terminals serve both the power and control circuits.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1DT25B7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110244540\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC, 25-400 Hz \/ ≤ 300 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie), AC-1, ≤440V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional Free-Air Thermal Current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at 60 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity at 440 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A, IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Time Withstand Current (Icw), 1 s\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 A at 40 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V, IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC, mirror contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp (power and control)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h at 60 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or screw-fixing plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20, front face\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 x 45 x 92 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e365 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection Notes\u003c\/h2\u003e\n\u003cp\u003eThe LC1DT25B7 switches 25 A AC-1 uniformly across all four poles, making it a fit for resistive heater or lighting banks that need four-pole isolation rather than three-phase motor duty. A 24 V AC coil matches the control-transformer secondary used on most European machine-tool panels. For the same coil voltage at higher resistive current, the 32 A and 40 A LC1DT variants share the same technology.\u003c\/p\u003e\n","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54077067526427,"sku":"LC1DT25B7","price":35.12,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1dt25b7-tesys-deca-contactor.jpg?v=1790875373","url":"https:\/\/stoklink.com\/products\/schneider-electric-lc1dt25b7-tesys-deca-contactor","provider":"Stoklink","version":"1.0","type":"link"}