{"product_id":"schneider-electric-lc1d150g7-tesys-deca-contactor-150a","title":"Schneider Electric LC1D150G7 TeSys Deca LC1D 3P 3NO AC-3 150 A 120 V AC Coil 1NO+1NC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D150G7 is a TeSys Deca 3-pole contactor rated 150 A in AC-3 at up to 440 V, which corresponds to 75 kW at 380\/400 V. It has three normally open power poles for circuits up to 1000 V AC, a 120 V AC 50\/60 Hz coil with a built-in transient suppressor and a 1NO+1NC auxiliary block with a mirror contact. Power connection uses screw connectors with 2 inputs.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D150G7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca (Advanced)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110527537\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles \/ contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, 3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation categories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3, AC-3e, AC-1, AC-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current AC-3 \/ AC-3e (at 60 °C, ≤ 440 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current AC-1 (resistive, at 60 °C, ≤ 440 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage, power circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 25...400 Hz; ≤ 300 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power AC-3 \/ AC-3e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kW at 220\/230 V; 75 kW at 380\/400 V; 80 kW at 415\/440 V; 90 kW at 500 V; 100 kW at 660\/690 V; 75 kW at 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power AC-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 kW at 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting diode suppressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil operating limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8...1.15 Uc at -40...55 °C; drop-out 0.3...0.5 Uc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil inrush \/ hold-in\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280...350 VA \/ 2...18 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC built in, NC mirror contact (IEC 60947-4-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1400 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand Icw, power circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1400 A for 1 s; 1200 A for 10 s (at 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse, power circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 A gG type 1; 250 A gG type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 cycles\/h at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRail, Plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 front face (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...60 °C; 60...70 °C with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e158 x 120 x 136 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eMarine\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 14\u003c\/li\u003e\n\u003cli\u003eJIS C8201-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 120 V AC 50\/60 Hz coil suits North American 120 V control circuits and also runs on 50 Hz supplies. The key rating is 150 A AC-3 at up to 440 V (75 kW at 400 V); the 200 A value is the resistive AC-1 rating and should not be used to size a motor feeder. It offers 1400 A breaking capacity at 440 V, and its maximum operating rate of 1200 cycles\/h makes it a fit for heavy motors with infrequent starts rather than high-cycle duty. The coil carries a built-in peak-limiting diode suppressor, so no separate surge module is needed for the control circuit.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54807660593435,"sku":"LC1D150G7","price":716.45,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d150g7-lc1d-contactor.jpg?v=1795503288","url":"https:\/\/stoklink.com\/products\/schneider-electric-lc1d150g7-tesys-deca-contactor-150a","provider":"Stoklink","version":"1.0","type":"link"}