{"product_id":"schneider-electric-gv6p500f-tesys-gv6-mpcb","title":"Schneider Electric GV6P500F TeSys GV6 3P 500 A 36 kA Thermal-Magnetic Motor Protection Circuit Breaker (MPCB)","description":"\u003cp\u003eThe Schneider Electric GV6P500F is a 3-pole TeSys GV6 motor circuit breaker rated 500 A, sized to protect 200-250 kW motors at 400\/415 V. It pairs an adjustable thermal-magnetic protection curve (Ir 250-500 A, class 5\/10\/20) with a 36 kA breaking capacity (Icu) at 400\/415 V, plus phase-loss, phase-unbalance and short-time-delay protection, operated by a direct rotary handle.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eGV6P500F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys GV6 (TeSys Giga)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice application\u003c\/td\u003e\n\u003ctd\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit technology\u003c\/td\u003e\n\u003ctd\u003eElectronic (thermal-magnetic characteristic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] rated current\u003c\/td\u003e\n\u003ctd\u003e500 A at 65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal setting range (Ir)\u003c\/td\u003e\n\u003ctd\u003e250-500 A, class 5\/10\/20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power\u003c\/td\u003e\n\u003ctd\u003e200-250 kW at 400\/415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e36 kA at 400\/415 V | 25 kA at 500 V | 10 kA at 660\/690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIcs rated service breaking capacity\u003c\/td\u003e\n\u003ctd\u003e100% at 400\/415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated conditional short-circuit current\u003c\/td\u003e\n\u003ctd\u003e35 kA at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnetic tripping current\u003c\/td\u003e\n\u003ctd\u003e6500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e800 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eCategory A (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eBars or lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003e50 N.m, M10 screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e255 x 140 x 179 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25 to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e5000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eChoose the GV6P500F where upstream prospective short-circuit current stays at or below 36 kA at 400\/415 V; for higher fault levels, the 70 kA GV6P500H variant shares the same 500 A frame and footprint without changing the thermal range. The 250-500 A thermal dial covers the full current band of 200-250 kW motors at 400\/415 V, and the three tripping classes (5\/10\/20) let the setting match motor starting duration, from normal duty to heavy-inertia loads. Internal mounting positions accept GV7-series auxiliary contact blocks (OF, SD) and voltage-trip releases (MN, MX) without a separate enclosure.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54077016473883,"sku":"GV6P500F","price":1197.41,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv6p500f-tesys-gv6-mpcb.jpg?v=1790874757","url":"https:\/\/stoklink.com\/products\/schneider-electric-gv6p500f-tesys-gv6-mpcb","provider":"Stoklink","version":"1.0","type":"link"}