{"product_id":"schneider-electric-gv4pem80n-tesys-gv4-mpcb","title":"Schneider Electric GV4PEM80N TeSys GV4 3P 80 A 50 kA Multifunction Motor Protection Circuit Breaker (MPCB)","description":"\u003cp\u003eThe Schneider Electric GV4PEM80N is a 3-pole TeSys GV4 motor circuit breaker rated 80 A continuous current with a 50 kA breaking capacity (Icu) at 380-415 V AC. It provides thermal-magnetic protection with NFC-adjustable multifunction motor protection for 3-phase motors from 22-37 kW at 400 V, with a 40-80 A thermal setting range and toggle start-stop control.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eGV4PEM80N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys GV4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606481310859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMotor circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Unit Technology\u003c\/td\u003e\n\u003ctd\u003eMultifunction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Rated Current\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Setting Range Ir\u003c\/td\u003e\n\u003ctd\u003e40-80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnetic Tripping Current\u003c\/td\u003e\n\u003ctd\u003e1360 A (17 x In)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity Icu (380-415 V AC)\u003c\/td\u003e\n\u003ctd\u003e50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage Ue\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage Ui\u003c\/td\u003e\n\u003ctd\u003e800 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIth (Conventional Free Air Thermal Current)\u003c\/td\u003e\n\u003ctd\u003e115 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage Uimp\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections\u003c\/td\u003e\n\u003ctd\u003eEverLink BTR screw terminals, 1.5-70 mm2 (top), 2.5-95 mm2 (bottom)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e5000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature for Operation\u003c\/td\u003e\n\u003ctd\u003e-25...70 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e155 x 81 x 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBeyond the 40-80 A thermal dial, the multifunction trip unit lets a technician tune short-time delay (Isd, 5-13 x Ir), phase unbalance and loss, ground-fault, locked-rotor and long-start protection over NFC from a smartphone, and accepts 1-2 external SDx modules for alarm and fault differentiation. The trailing N in the catalog number identifies the breaking-capacity class Schneider assigns within the GV4 range (B\/N\/S step up from economy to high short-circuit withstand); this unit falls in the standard 50 kA tier, so it should be matched to the prospective short-circuit current at the installation point rather than swapped for a lower class to save cost on a feeder with higher fault levels. For the 80 A frame, internal mounting positions accept OF\/SD auxiliary contact blocks and MN\/MX voltage trip units without changing the breaker's footprint, which keeps a panel design consistent across the motor power range it covers.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230506193179,"sku":"GV4PEM80N","price":689.82,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv4pem80n-tesys-gv4-mpcb.jpg?v=1790900921","url":"https:\/\/stoklink.com\/products\/schneider-electric-gv4pem80n-tesys-gv4-mpcb","provider":"Stoklink","version":"1.0","type":"link"}