{"product_id":"schneider-electric-gv2le14-tesys-deca-gv2le-manual-starter","title":"Schneider Electric GV2LE14 TeSys Deca GV2LE 10 A Manual Starter and Protector","description":"\u003cp\u003eThe Schneider Electric GV2LE14 is a TeSys Deca GV2LE manual motor circuit breaker rated at 10 A, giving magnetic-only short-circuit protection to a 3-phase motor branch. A toggle handle provides local on\/off\/trip control, and the breaker carries a 100 kA breaking capacity (Icu) at 400\/415 V. Because the trip unit is magnetic only, it is normally combined with a separate thermal overload relay.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eGV2LE14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eGV2LE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eMotor circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3389110516975\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit technology\u003c\/td\u003e\n\u003ctd\u003eMagnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine rated current\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnetic tripping current\u003c\/td\u003e\n\u003ctd\u003e149 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free-air thermal current\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity (Icu) at 400\/415 V\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated service breaking capacity (Ics) at 400\/415 V\u003c\/td\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power at 400\/415 V\u003c\/td\u003e\n\u003ctd\u003e3 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power at 690 V\u003c\/td\u003e\n\u003ctd\u003e5.5–7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIK04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, or panel-screwed with adaptor plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e45 x 89 x 78.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.33 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature, operation\u003c\/td\u003e\n\u003ctd\u003e-20…60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eLROS (Lloyd's Register of Shipping)\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eRINA\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003cli\u003eIEC\/EN 60335-2-40 Annex JJ\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe GV2LE trip unit is magnetic only, with a fixed 149 A instantaneous trip point set for the 10 A line rating — it carries no thermal overload element, so pair it with a TeSys LRD-type thermal relay, or use it ahead of a soft starter or drive that already provides overload protection. Its 100 kA breaking capacity at 400\/415 V and 690 V toggle rating cover the full 3–7.5 kW motor power range this reference is rated for, so choosing between GV2LE variants comes down to the required line current, not the breaking capacity. The screw-clamp power terminals take 1–6 mm² solid conductor, which sets the practical upper wiring size for the 10 A circuit; the IK04 impact rating and -20…60 °C operating range are the same across the GV2LE line, so they do not factor into which current rating to pick.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eManual disconnect and short-circuit protection ahead of a contactor, soft starter, or variable frequency drive on a 3-phase motor branch circuit, in panels where a separate device provides continuous-current overload protection. The 690 V insulation and impulse withstand rating (Ui, Uimp) allow the same reference to be used on 400\/415 V branch circuits with margin, or on circuits run closer to its 690 V operational limit where the breaking capacity drops to 3 kA.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230493577499,"sku":"GV2LE14","price":47.41,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv2le14-gv2le-manual-starter.jpg?v=1790279472","url":"https:\/\/stoklink.com\/products\/schneider-electric-gv2le14-tesys-deca-gv2le-manual-starter","provider":"Stoklink","version":"1.0","type":"link"}